Tempsens CALsys 1200 Скачать руководство пользователя страница 3

1. General Instruction

1.1 Information on operating instruction

Congratulations   on   your  purchase   of  high-quality  and  efficient  CALsys   1200   temperature

calibrator.Read this manual carefully to all instructions on safety, operation and maintenance. It
serves as an important source of information and reference for installation and operation of the

device.   The   general   safety   requirements  must  be  strictly   adhered   to  when   operating  the
device.  The  fact  contained   especially  safety   are  observed.  If   you   experience   any  further

questions, please contact our technical support by phone or mail to [email protected]

1.2 Liability and warranty

This instrument has been manufactured to exacting standards and is warranted for  twelve

months against electrical breakdown or mechanical failure caused through defective material or
workmanship, provided the failure is not the result of misuse. In the event of failure covered

by   this   warranty,   the   instrument   must   be   returned,   carriage   paid,   to   the   supplier   for
examination and will be replaced or repaired at our option.

I NT ER F E RE N C E   WIT H   OR   F AI L U R E   T O   PR O PE R L Y   M A I NT A I N   TH I S   I N ST R UM E NT   M A Y
I N V A L I D T HI S   WA RR A NT Y .  

1.3 Unpacking & Initial Inspection

Our   packing   department   uses   custom   designed   packaging   to   send   out   your   unit,   but   as
accidents can still happen in transit, you are advised, after unpacking the unit, to inspect it for

any sign of damage, and confirm that your delivery is in accordance with the packing note. If
you   find   any   damage   or   find   any   part   missing   during   delivery   notify   us   and   the   carrier

immediately.   If   the   unit   is   damaged   you   should   keep   the   packing   for   possible   insurance
assessment.    

After unpacking you will find following items.

 

 

   Calsys 1200

     N type TC          Inconel Block

  Software CD 

  RS-232 cable

  Insulation wool         Tongue Tool

      Power cable

      

(Block remover)

Содержание CALsys 1200

Страница 1: ...CALsys 1200 CALsys 1200 Dry block Temperature Calibrator USER MANUAL TEMPSENS INSTRUMENT I PVT LTD UNIT II...

Страница 2: ...2 Circuit diagram 4 Overview 4 4 1 Introduction 4 2 Outline description 5 Operating Instruction 5 5 1 Power 5 2 Setting the temperature 5 3 Operating Instruction 6 Operation of Controller 6 6 1 The T...

Страница 3: ...ctive material or workmanship provided the failure is not the result of misuse In the event of failure covered by this warranty the instrument must be returned carriage paid to the supplier for examin...

Страница 4: ...for repair Do not use the apparatus outside its recommended range i e 250 to 1200 C Ensure inflammable materials are kept away from hot parts of the apparatus to prevent fire risk Before connecting to...

Страница 5: ...ge 250 to 1200 C Resolution 0 1 C Stability 0 5 C Controlling sensor R type T C Time to reach max Temperature 90 Min Operating Temperature 20 to 45 C Controller Specifications Eurotherm Stabilization...

Страница 6: ...The CALsys models are part of wide range of portable calibrators designed and made by us Please contact us in case you required more information about our other products 4 2 Outline Description The c...

Страница 7: ...ze the temperature bath within 0 5 C of the set point 5 3 Operating Instruction 1 Insert the inconel block into well of furnace 2 Connect the CALsys 1200 to a suitable power supply Switch ON the Dry b...

Страница 8: ...point to the required value The lower display changes to indicate the new set point 6 3 Monitoring the Controller Status A row indicate the controllers status as follows OP1 Heat Output OP2 Cool Outpu...

Страница 9: ...recommended Cleaning may be accomplished by the use of a small dry paint brush 7 2 Trouble shooting 1 Unit fails to operate Check fuse if it is tripped switch is ON If not power ON of calsys 1200 bat...

Страница 10: ...f software 1 2 Parameter in mainscreen 1 2 1 Communication Communication between the furnace and the software is implemented via a RS 232 cable connected between the furnace and the PC serial port Thi...

Страница 11: ...ging up to 120 minutes than clickon start graph button After complete the task clickon save to file button Set Point C in which you can set temperature of furnace as your requirement PVI Value Read th...

Страница 12: ...th silicon gel to protect it from humidity Warranty TEMPSENS CALsys 1200 instrument have a warranty of one year from the invoice date This warranty covers manufacturing defects User induced faults are...

Страница 13: ...TEMPSENS INSTRUMENT I PVT LTD...

Отзывы: