17
▪
It is recommended to test that the device works correctly before any real use. To test this, you only need to place
your hand in front of the laser beam to trigger the alarm. You only need to press any of the buttons on the
keyboard to stop the alarm.
Once the alarm has been stopped, monitoring must be restarted by selecting a threshold again.
The Leader SENTRY Wireless has 3 alarm rates:
1 to identify when a threshold has been exceeded.
1 to identify an error message Exxx (see §
7).
1 to signal low battery level.
NB:
See Meaning of Visual & Audible Alarms (
see § 5.2.1)
.
▪
The
Leader SENTRY Wireless
is designed to detect movement in the axis of the laser range finder beam. To monitor
the two axes simultaneously, two devices can be used together and operated from the same control screen.
4.6.1
VIEW ALL function
Function accessible by pressing the button.
▪
The
VIEW ALL
screen is only available if at least two devices are all connected.
LASER 1 name
(Capital letters)
’’LA1’’
.
LASER 2 name
(Lower case letters)
’’la2’’
.
Selected threshold value.
Battery indicator for
LASER 1
.
Icon which indicates that the sound alarm is deactivated (here for
LASER 1
).
Icon that indicates that the sound alarm has been activated (by default when the laser range finder is turned on).
E.g.
LASER 1
and
laser 2
connected.
If
LASER 1
detects a movement exceeding the
threshold, it triggers the visual alarm (flashes) - silent
mode.
If
laser 2
detects a movement exceeding the threshold,
it triggers the sound alarm (siren) and visual alarm
(flashes).
LASER 1
screen with 100 mm (0.33ft) threshold
and
laser 2
with 5 mm (0.02ft) threshold
LASER 1
Structure
Lasers