28
6
WARNING
LEADER
, and its subsidiaries, accepts no responsibility for any direct, indirect or accidental damage related to the
supply, performance or use of the
Leader SENTRY Wireless
movement monitor.
7
TROUBLESHOOTING
The device does not turn on
- Check that the batteries are new and fully charged
- Check that the battery insertion direction is correct
- Check that the batteries are the correct type
- Check that all batteries are identical
- Check that the electrical power supply cable is not damaged
- Check that the battery tray tips are not damaged
- Check that the power supply connector is correctly attached.
- Check that the energy source is the correct voltage (12V), direct or
through the external 110-220V adapter
- Check that the external battery (optional) is charged
- Check that the battery pack (optional) is connected
No distance is displayed
- Reduce the distance between the laser and the target
- Clean the laser range finder protective window
The laser dot is not visible
- The laser range finder dot as well as the laser pointer dot are not always
visible in high light levels
- Aim at a target in shadow if possible
- Place the palm of your hand in front of the laser range finder's lens, a red
dot should appear
- Make sure that the cross-hair is aligned with the target and the distance is
correctly displayed
@E203
Contact LEADER
@E211
Contact LEADER
@E220
Contact LEADER
@E234
Distance outside the scope of
measurement
- Bring the target next to the laser
- Clean the laser protective window
@E252
Temperature too high
(> 50°C in the laser box)
- Ideally place the device in shadow. Ditto with the external
optional battery if used. For a successful measurement, the range finder
only works between -10 and 50°C
@E253
Temperature too low
(< -10°C in the laser box)
- Place the device near to a source of heat or in the sun
For a successful measurement, the range finder only works between
-10 and 50°C
@E255
Weak signal or distance
outside the limits
- Use a more reflective target, shorten the distance between the laser and
the target
- Clean the laser protective window
@E256
High signal
- Use a less reflective target
@E257
Signal (SNR) too weak
(background light too
intense)
- Use a more reflective target, shorten the distance between the laser and
the target
-Too much light in environment
@E259
Power supply too
low for
measurement
- Check that the batteries are the correct type
- Change the batteries
- Check that the external battery (optional) is charged
@E260
Signal too unstable for
measurement
- Use a more reflective target, shorten the distance between the laser and
the target
@E555
Laser response time above
2s when a threshold is
triggered
- Use a more reflective target, shorten the distance between the laser and
the target.
- Clean the laser protective window.