21
5.2
Alarm operating principle
▪
A detected movement triggers the sound alarm (siren) and visual alarm (3 flashes) for the laser range finder in question
(when exceeding the selected threshold).
For example, when using a Sentry DOUBLE, the lasers trigger the alarm independently. If the laser range finders
trigger their alarm, it is because the 2 laser range finders detect a movement in each of the targets.
▪
If there is a measurement error with the threshold met, the laser in question displays a code
Exxx
and triggers an
alarm. This has a different rate than the alarm detecting a movement (see
§ 5.2.1).
▪
If the alarm is triggered, a remote control connected to 1 or 2 laser range finders relays the sound alarm. It includes
a speaker generating an
80dB
alarm (no light flash).
▪
The name of the device that detected the movement is displayed by default on the screens of all of the connected
devices.
o
LASER 1 simulation which triggers the alarm
o
Simulation: LASER 1 and LASER 2 both trigger their alarm.
▪
The user can stop the alarm by pressing on any button of any device.
It will therefore be necessary to select a threshold to restart monitoring of the laser which sounded.
If the laser range finder which sounded is part of a Sentry DOUBLE (2 connected lasers), the 2nd laser range
finder which did not detect any movement keeps its programming.
2 flashes/5 sec
1 flash/5 sec
2 flashes/sec
1 flash/sec
2 flashes/5 sec
1 flash/5 sec.
2 flashes/sec
1 flash/sec
LA2
LA2
LA2