KEH-10150
Hydraulic Crimping Tool
www.grupotemper.com
The dusty and air will caused the tool does not working or the sealing
kits lose their function. Keep the oil clean during changing the
oil and avoid the dusty into the hydraulic system. Waiting for a little
to exhaust the air which in the oil hose, then insert the oil plug.
.
Please lock the pump handle to avoid the air into the hydraulic system.
Wear the rubber gloves to avoid touching the oil, if the skin touches the oil please
wash it by soap water. To protect the environment please draining the oil to the
department which appointed by local government.
5.
after a long time using, the sealing kits will be damaged, if there is leakage please
contact with the manufacturer and/or the distributor to change the sealing kits.
Troubleshooting
Fault cause
Analysis
Solution
A.
Not enough pressure
1.not enough oil with
the tool
2.The dusty into the
hydraulic system
3.Inner leakage
1.
Fill the oil
2.Change the oil as above instruction
3.Contact with manufacturer and/or
distributor
B.
Not tight enough with
the connector and the
cable after crimping
1.
Not reached rated
pressure
2.Wrong die
1.Reference to the instruction A.
2.Select the right die
C.
Much Flash made after
crimping
1.Wrong die
1.
Select the right die
D. Leakage on the head or
plunger
1.Sealing kits broken
1.Contact with manufacturer and/or
distributor or ask the trained person to
change