TEMCO GAS LOGS & FIREPLACES 

INSTALLATION AND STARTUP CHECKLIST 

Customer Copy 

NOTE:  

TEMCO

  gas logs and fireplaces require installation by a qualified gas appliance installer.   A copy of this checklist must be 

submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.

 

All Vent-Free Gas Fireplaces and Logs  

                

Read and understand installation instructions before attempting installation. 

                 Assure that the model to be installed is of the CORRECT FUEL TYPE.  Check markings on the shipping container  (Model#s 
                 ending in “N” are natural gas products; model#s ending in “P” are LP gas products.), tags on the burner assembly, and 
                 color of the ODS safety pilot tube. 

                 (Aluminum for natural gas; brass for LP gas) 

                

Notes:  

REGULATORS ARE NOT FIELD-ADJUSTABLE.  ANY ATTEMPT TO ADJUST VOIDS THIS WARRANTY.  

                 In order to ensure adequate combustion air, make sure that the model being installed has the appropriate heating 
                 capacity for the unconfined space available.  

Allow a minimum of 50 cubic feet of unconfined space per 1000 BTU’s for all 

                 gas appliances. 

                 Assure that gas line size is adequate for the model’s input rating (BTU’s per hour), the length of run form the meter       or second 
                 stage regulator to the farthest gas appliance, and other gas appliances on the system.  A drip leg or sediment trap is required.  
LP            models require a minimum tank size of 120 gallons water capacity and two stage regulation. 

                 Assure that installation meets local codes and ordinances. 

                 Assure that there are no fans or blowers in the fireplace area. 

                 Check for leaks before lighting. 

                

Using a manometer, verify proper gas pressure at the manifold with unit at maximum setting and other appliances 

                 operating. 

                

inlet pressure:__________ (ins. wc)          manifold pressure:__________ (ins. wc) 

                 Verify proper ignition of ODS and front and rear burners, as well as proper appearance of flames. 

                

Verify that ceramic fiber and refractory components are properly positioned and secure.  

(Rear burner must not contact 

                 logs.) 

                 Verify adequate clearance to mantels and other combustibles. 

                 Demonstrate correct operation of the product to the consumer.  Note:  LP models must not be operated if fuel tank is less than 
                 1/4 full. 

                 Observe the consumer operating the product properly. 

                 Explain and demonstrate proper periodic maintenance. 

                 Explain that operation with logs positioned other than as described in the manual voids the warranty and will cause      p

o

o

                 combustion and sooting. 

                 Verify the consumer’s understanding that warranty service work that is not pre-approved by the manufacturer’s Technical 
                 Service Department (other than routine maintenance) may not qualify for reimbursement. 

                 Answer any questions the consumer may have about 

TEMCO 

vent-free products. 

Vent-Free Gas Logs Only 

                

Verify that the fireplace in which the logs are to be installed is either a solid-fuel burning fireplace (either factory-built or 

                 masonry) with a working flue system connected to it or an approved vent-free firebox. 

                 Verify that the fireplace has been thoroughly cleaned by a professional chimney sweep.  If solvents have been used to clean 
                 the hearth, they must be allowed to evaporate before proceeding with installation. 

                 Check firebox dimensions for adequate height, width, and depth. 

                 Verify that the grate assembly is attached to the firebox floor. 

                 Verify that any ash dump or outside air inlets are permanently sealed to avoid drafts within the firebox. 

                 Verify that no additional logs, ornaments, or non-approved blower devices have been added. 

                 Repair any broken or damaged logs prior to operation. 

                 Check mantel clearances and verify installation of canopy if necessary. 

                 Glass doors must be removed or opened completely during operation of logs. 

 

Please sign below that checklist has been completed and understood.  DATE INSTALLED ______/______/______ 

 

 

Installer                                            Phone                        Consumer                                          Phone 

 

Содержание PS24MN

Страница 1: ...asoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation ...

Страница 2: ...bleshooting 14 Repair Parts 15 Parts List 15 Warranty Information 16 Installation and Startup Checklist 17 18 Warranty Registration 19 2 MINIMUM DIMENSIONSFOREXISTINGSOLIDFUELBURNINGFIREPLACES HEARTH SIZE TABLE Opening Height H Front Width A Rear Width B Depth C PS24MN 18 30 21 15 PS24MP 18 30 21 15 B C A OPENING HEIGHT H This appliance may be installed in an aftermarket permanently located manufa...

Страница 3: ...mine if unvented heaters are permitted If unvented heaters are not permitted the fireplace chimney damper must be fixed at a minimum free vent opening area of 15 sq ins This must be accomplished by a clamp or screw on the chimney damper to stop at the minimum vent area The fireplace must also have a minimum free vent opening of 15 sq ins see figure 1 This appliance may be installed in an after mar...

Страница 4: ...Gas range 60 000 BTU Hr Vent free logs 29 000 BTU Hr Total 89 000 BTU Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU Hr the space can support with the actual amount of BTU Hr used __________ BTU Hr maximum the space can support __________ BTU Hr actual amount of BTU Hr used Example 100 000 BTU Hr m...

Страница 5: ...o permanent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or o...

Страница 6: ...ind the front grate legs and should be used for securement of the log set After locating the chassis correctly in the fireplace mark the hole positions on the fireplace floor Drill two 1 8 diameter holes approximately 1 2 deep Use the two screws to secure the chassis to the fireplace floor see figure 3 CLEARANCES NOTE The following instructions regarding installation clearances and the use and ins...

Страница 7: ...pliance we recommend a minimum 200 pound cylinder with a fill gauge Use of a 100 pound cylinder is not recommended Other household gas appliances may require the tank size to be larger Use pipe wrenches when making the connection to the valve to prevent turning or damage to gas valve Connection between the manual shutoff valve and the gas valve can be made with an CSA design certified flexible con...

Страница 8: ...llation is complete Under no circumstances should internally zinc alloy coated piping be used According to the LP Gas Code and National Fuel Gas Code If galvanized piping is used it must be EXTERNALLY coated only Galvanized water pipe used for gas installations will result in reduced gas pressure and gas leaks GAS VALV IF USING FLEXIBLE CHECK LOCAL CODES FOR SPECIFIC REQUIREMENTS LESS THAN 6 FEET ...

Страница 9: ...gulator Pressure 4 5 ins WC 10 ins WC Minimum inlet supply pressure for the purpose of input adjustment Outside Diameter Copper Tubing Type L 1 000s BTU Hr Tubing Length Feet 1 2 0 43 5 8 0 545 3 4 0 666 7 8 0 785 10 110 206 348 536 20 76 141 239 368 30 61 114 192 296 40 52 97 164 256 50 46 86 146 224 60 42 78 132 203 80 36 67 113 174 100 32 59 100 154 WARNING Use only internally tinned copper tub...

Страница 10: ...ovided NOTE This clip maintains upright position of middle log to optimize glowing ember front surface See clip location in Figure 6A When you have completed these steps compare log positions with Figure 6A The logs must be positioned as illustrated The top twig may be positioned as shown in either Figure 6B or Figure 6C The top twig must be placed in the notches provided on top of the rear and ce...

Страница 11: ...fter several tries turn the gas control knob to OFF and call your service technician or gas supplier When the pilot remains lit turn gas knob counterclockwise to the HIGH position Depress the knob slightly and turn counterclockwise to the setting you prefer The front burner may be turned on or off Turn knob located on right hand side of the control panel to ON or OFF position Do not leave in an in...

Страница 12: ...ppliance is operating Close supervision is necessary when the appliance is being operated near children Do not use to cook food If this is the ONLY gas appliance w e recommend a minimum 200 pound cylinder with a fill gauge Use of a 100 pound cylinder is not recommended Other household gas appliances may require the tank size to be larger Do not operate the vent free fireplace if the fuel level in ...

Страница 13: ...ront grate or the control knob panel may be required occasionally Do not use any cleaning fluids to clean the logs or any other part of the appliance If the flames show any unusual shapes or behavior or if the burner s fail to ignite properly then the burner holes may require cleaning If this occurs contact your nearest dealer to get the appliance serviced Alternatively the appliance can be cleane...

Страница 14: ...service operation Always check for gas leaks after servicing SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION 1 Pilot will not light Air in the gas line Low gas pressure Gas supply turned off Blockage in gas line ODS pilot orifice is clogged Control knob not in pilot position Control knob not pressed in while in pilot position Ignitor did not spark Ignitor electrode positioned wrong Ignitor electrode brok...

Страница 15: ... TUBE PILOT 76784 76784 1 9 GAS VALVE 76721 76722 1 10 REGULATOR SCP 74557 73333 1 11 REGULATOR BRACKET 76754 76754 1 12 IGNITOR W NUT PIEZO 65180 65180 1 13 WIRE IGNITOR AD COMMON 74017 74017 1 14 MANIFOLD TUBE SPLIT NUT 76519 76519 1 15 MANIFOLD TUBE SPLIT NUT 76520 76520 1 16 INJECTOR 43 NATURAL 76775 1 17 INJECTOR 49 NATURAL 76771 1 18 INJECTOR 56 PROPANE 76776 1 19 INJECTOR 1 45 PROPANE 76774...

Страница 16: ...l codes and ordinances The logs must be placed strictly in accordance with the arrangement described in the installation instructions The Product must be operated and maintained according to the instructions furnished Alteration of the Product in any way is prohibited and voids any and all warranties Removal of the data plate alters the Product and voids the warranty The installer must have comple...

Страница 17: ...ODS and front and rear burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer Note LP models must not be operated if fuel tank is less than 1 4 full Observe the consu...

Страница 18: ...f ODS and front and rear burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer Note LP models must not be operated if fuel tank is less than 1 4 full Observe the con...

Страница 19: ... have followed all codes and regulations and adhered to the TEMCO installation instructions I have completed the proper installation and startup checklist Installers Signature Print Installer s Name Purchaser Address Phone Retailer Address Phone Date of Purchase WARRANTY REGISTRATION Please Answer the Following Questions Check Box 1 Type of Home Single Family Duplex Apt Mobile Home Cabin Vacation ...

Отзывы: