76658
Fuel Conversion Instructions
WARNING: This HI/LO conversion kit must ONLY
be applied as part of a conversion kit supplied by
the appliance manufacturer for the specific appli-
ance and type of gas being converted.
The conversion shall be carried out in accordance
with the requirements of the provincial authorities
having jurisdiction and in accordance with the
requirements of the CSA B149.2 installation Code
(Canada) and with the requirements of the National
Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING: This conversion kit shall be installed by
a qualified service agency in accordance with the
manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in this instruction is
not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property
damage, personal injury or loss of life. The quali-
fied service agency is responsible for the proper
installation of this kit. The installation is not proper
and complete until the operation of the converted
appliance is checked as specified in the
manufacturer’s instructions supplied with the kit.
Installer Notice: Using an ink pen, fill out the re-
quired information on the conversion label. Re-
move the backing from label and stick label in a
visible position on bottom of fireplace close to gas
valve.
Installer Notice: These instructions must be left
with the appliance.
Instructions for converting your fireplace from Natural
gas to Propane/LP gas.
All fireplaces are shipped from the factory equipped to
operate on Natural gas. To convert the fireplace to
operate on Propane/LP gas, follow the instructions
below. Please see the appropriate parts list for your
model for parts included with our fireplace.
Check the items in the kit with the parts list. Notify the
supplier of any items that are missing before installing
the conversion kit.
1. Turn off the gas supply.
2. Turn off the electrical supply to the appliance if so
equipped.
To Replace Burner Orifice
1. Remove lava rock to expose screws and remove
grate assembly.
2. Use screwdriver and bend holding tabs down and
forward (Fig. 40 & 41)
Burner
Orifice
Holding Tabs
T205
Fig. 40 Bend holding tabs down and forward.
1/8” When Gas Tight
Bend Tabs Down
Remove Burner Orifice
T206
Fig. 41 Move burner tube to replace orifice.
3. Move the burner to the left and off of the burner
orifice (Fig. 41)
4. Using a suitable tool replace natural orifice #46 with
propane orifice #56 for model DV1000MBN or
replace natural orifice #45 with propane orifice #55
for model DV1200MBN, or replace natural orifice
#42 with propane orifice #54 for model DV1400MBN
furnished with conversion kit. Tighten orifice with
suitable tool until gas tight. (Fig. 40)
5. Move burner back to original position tight to orifice
and bend tabs back up.
6. Set the air shutter opening for the correspond-
ing gas used. (Refer to Figure 42 and Chart on
Page 32)
7. Replace grate assembly.
Fig. 42 Air shutter settings for propane/LP gas.
T206
3/32” - DV1000
3/16” - DV1200
1/4” - DV1400