![Temco DV1000MBN Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/temco/dv1000mbn/dv1000mbn_homeowners-installation-and-operating-manual_1085314010.webp)
10
Temco DV1000/1200/1400MBN Series
76658
NOTE: Use only venting systems and components as
certified with the appliance. Use of uncertified vent
systems or components will void the warranty and may
compromise the operation of the fireplace, its systems,
and components as certified with the appliance.
0
5’
46"
(1168mm)
33
¹⁄₂
"
(851mm)
10’
15’
25’
30’
32’
0
3’
5’
10’
15’
A vent guard should be used
whenever the termination is
lower than the specified
minimum or as per local
codes
*
Min. Refer to Chart on Page 5.
*
T180
Fig. 12 Venting graph.
2" (51mm)
1" (25mm)
1"
(25mm)
Top of Vent
Combustibles
NOT Allowed in
Shaded Area
4” Dia. Flue
7” Dia.
Intake
Vent
T181
Fig. 11 Vent clearances.
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
A =
Combustible
6"(152mm)
Noncombustible
2"(50mm)
B =
Combustible
6"(152mm)
Noncombustible
2"(50mm)
A
Balcony -
with no side wall
G =
Combustible &
Noncombustible
12"(305mm)
G
Balcony -
with perpendicular side wall
H = 24"(610mm)
J = 20"(508mm)
H
J
B
Recessed Location
C = Maximum depth of 48"
(1219mm) for recessed
location.
D = Minimum width for back wall
of a recessed location.
Combustible 38"(965mm)
Noncombustible 24"(610mm)
E = Clearance from corner in
recessed location.
Combustible 6"(152mm)
Noncombustible 2"(50mm)
C
D
C
E
V
V
Combustible &
Noncombustible
V
V
V
584-15
Fig. 10 Termination1 clearances.