21
Temco DV1000/1200/1400MBN Series
76658
TL121
Fig. 34 DV1000MBN and DV1200MBN logs in final posi-
tion.
Thermostatic Fan Kit - Optional
(Part #CDVTFK or # GDVTFK)
For installation of the optional fan, please refer to the
instructions included in the fan kit.
Electrical Services
Optional fan kits are equipped with a 120V, 60Hz
blower, less than 12 amps.
If electrical supply 120V is being roughed in to provide
for future installation of an optional blower kit, an
approved surface mount, steel electrical box, cover and
strain relief bushing must be installed in the fireplace
(supplied by others).
NOTE: All electric connections are to be made in
accordance with CSA Standard C22.1 - Canadian
Electrical Code part 1 or with the National Electrical
Code, ANSI/NFPA 70 (latest addition) and/or in accor-
dance with local codes.
Speed Control Switch
1. The blower combination on/off switch and electronic
speed control is supplied loose to allow mounting in
a conveniently located wall mounted electrical box.
2. Wire speed control into black (hot) side of 120V,
60Hz line as shown in blower wiring diagram.
M
White
Black
G
Green
Fan
Temperature
Sensor
120
Volt
Speed
Control Switch
T173
Fig. 36 Fan wiring diagram.
CAUTION: Should this fan require ser-
vicing, the power supply must be discon-
nected.
Millivolt System
CAUTION: At installation and/or after any
service work or repairs glass door must be
removed before proceeding to lighting
instructions.
CAUTION: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation.
Verify proper operation after servicing.
Burner On/Off Control
All models may be used with an optional wall switch
that turns the main burner on or off. Optional millivolt
thermostats (GFPMT) and remote control may be
substituted for the wall switch (For installation of these
options, detail instructions are provided with optional
kits).
CAUTION: If the remote receiver is located in the gas
control area (under the firebox), clearance should be
below the firebox at least 2” (51mm) to avoid high
temperatures (receiver should not be exposed to
temperatures exceeding 130
°
F).
If your fireplace is equipped with a remote control
device, the batteries in BOTH the remote receiver and
the hand held control must be replaced at least once a
year. Refer to instructions provided with optional kits.
Back
Log
Twig
Front Log
TL122
Fig. 35 Side view of logset. (NOTE: The side logs for the
DV1400 are not shown.)
Slot
Bracket
Bracket