Temco DV1000/1200/1400MBN Series
76658
Sidewall (General) Venting Information
Fig. 15 Locate vent opening on wall.
Framing
Detail
9
³⁄₄
"
(248mm)
10
³⁄₄
"
(273mm)
Fireplace Hearth
Rnd.
8" Dia.
(203mm)
Min.
Opening for Noncombustible Wall
Fireplace Hearth
VO584-100
Vent Opening for Combustible Wall
5
⁷⁄₈
”
(149mm)
4
⁷⁄₈
”
(124mm)
Figures 15 and 16 show examples of horizontal termi-
nation arrangements using two 90
°
elbows (Rigid
Vent).
NOTE:
1. A maximum of two 90
°
elbows are permitted.
2. A minimum of 10’ (3m) vertical from base of unit is
required if two 90
°
elbows are used.
3. Minimum distance between elbows is 2’ (610mm).
4. Determine the permitted range of horizontal termi-
nation arrangement by using chart above and
deducting 3’ (914mm) from the maximum horizontal
distance for the second 90
°
elbow.
33"
(838mm)
Minimum
53" (1346mm)
Maximum
28’ (8.5m)
2’ (610mm)
Minimum
B
12" (305m
m)
Minim
um
A
10’ (3m
)
Minim
um
If length "B" is increased,
length "A" must be decreased
by a corresponding amount
A vent guard should be used
whenever the termination is
lower than the specified
minimum or as per local
codes.
T184
Fig. 16 Horizontal vent run.
Flex Venting
•
Flex vent shall use the spacer springs as included
every foot to ensure proper vent operation.
•
The 4” x 7” flex system may be used for all sidewall
applications and vertical venting up to 35’ (10.7m).
•
Flex shall be properly supported so there are no
sags in the system. Supports must be used at least
every 24” (610mm) on horizontal section and every
36” (914mm) on vertical. Wire or metal stripping
may be used to support the venting.
Roof Pitch
H (Min.)
Flat to 6/12
12” (305mm)
6/12 to 7/12
15” (381mm)
Over 7/12 to 8/12
18” (457mm)
Over 8/12 to 16/12
24” (610mm)
Over 16/12 to 21/12
36” (914mm)
H
12
x
Vent Cap
Lowest Dis-
charge Opening
Gas Vent
Roof Pitch
is X/12
H (Min.) - Minimum height
from roof to lowest
discharge opening
T183
Fig. 14 Vertical termination location.
T182
NOTE:
Apply sealant “Mill-Pac” to innerpipe and “Mill-Pac” or high
temp silicone sealant to outer pipe. Sealant should be
applied at every joint in the vent system including at the
fireplace and at the vent terminal.
Fig. 13 Apply sealant at every joint in vent system.
MILL-PAC
MILL-PAC