![TEM EX10200006 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/tem/ex10200006/ex10200006_user-manual_1085228031.webp)
30
Minimum value is 1, maximum value is 9. If a value is entered other than those, filter will use
its default value.
7.2 Average Length (50)
If the scale is approved model, it cannot be changed. Some models may not have this menu.
Minimum value is 10, maximum value is 50. If a value is entered other than those, filter will
use its default value.
7.3 Minimum Average Length (5)
If the scale is approved model, it cannot be changed. Some models may not have this menu.
Minimum value is 1, maximum value is 25. If a value is entered other than those, filter will
use its default value.
7.4 Filter Break Count Value
If the scale is approved model, it cannot be changed. Some models may not have this menu.
Minimum value is 70, maximum value is 2800. If a value is entered other than those, filter
will use its default value.
8. Calibration:
8.1 Calibration Coefficient
It can be changed only if the calibration key is ON.
8.2 Maximum Capacity
It can be changed only if the calibration key is ON.
8.3 Division (1)
0: 3000
1: 2 x 3000
2: 3 x 3000 (not valid for approved models)
3: 6000 / 7500 (not valid for approved models)
4: 12000 / 15000 (not valid for approved models)
6: 1500 (It can be changed only if the calibration key is ON.)
8.4 Load Cell Maximum Capacity
It can be changed only if the calibration key is ON.
8.5 Device Unit (1)
0: g
1: kg
2: ton
It can be changed if it is approved model.
8.6 Gravity (“G”) value of the location where scale is calibrated (9.8022)
It can be changed only if the calibration key is ON.
8.7 Gravity (“G”) value of the location where scale will be used (9.8006)
It can be changed only if the calibration key is ON.
Содержание EX10200006
Страница 1: ...USERS GUIDE for WEIGHING PRICE COMPUTING COUNTING SCALES ...
Страница 3: ...2 PRICE COMPUTING SCALES ...
Страница 15: ...14 WEIGHING SCALES Except EKO ...
Страница 26: ...25 WEIGHING SCALES EKO ...
Страница 33: ...32 COUNTING SCALES ...
Страница 129: ...ACHTUNG Nach Verlassen des Setup Menüs schalten Sie die Waage aus und wieder ein ...
Страница 135: ...UWAGA Po wyjściu z menu ustawień należy wyłączyć wagę i włączyć ją ponownie ...