12
8.2 Maximum Capacity
It can be changed only if the calibration key is ON.
8.3 Division (1)
0: 3000
1: 2 x 3000
2: 3 x 3000 (not valid for approved models)
3: 6000 / 7500 (not valid for approved models)
4: 12000 / 15000 (not valid for approved models)
6: 1500 (It can be changed only if the calibration key is ON.)
8.4 Load Cell Maximum Capacity
It can be changed only if the calibration key is ON.
8.5 Device Unit (1)
0: g
1: kg
2: ton
It can be changed only if the calibration key is ON.
8.6 Gravity (“G”) value of the location where scale is calibrated (9.8022)
It can be changed only if the calibration key is ON.
8.7 Gravity (“G”) value of the location where scale will be used (9.8006)
It can be changed only if the calibration key is ON.
8.8 Load Cell mV/V value
mv/V value of the Load Cell used.
9. Relay Settings:
Not valid for this model.
10. Interface Settings:
(Valid only for PRINTER/PC type scales)
10.1 Communication ON/OFF (On)
If it is ON : RS232 communication is active.
If it is OFF : RS232 communication is inactive.
(It must be activated only for printer/pc type scales; otherwise ER 8 will occur.)
10.2 ID Number (8888)
ID number that will be sent to PC at the beginning of each data transmitted.
10.3 Continuous Transmitting (Off)
If it is ON : Activates continuous data transferring from scale to a PC.
If it is OFF : Communication is not continuous, data is sent when a request received from a
PC.
Содержание EX10200006
Страница 1: ...USERS GUIDE for WEIGHING PRICE COMPUTING COUNTING SCALES ...
Страница 3: ...2 PRICE COMPUTING SCALES ...
Страница 15: ...14 WEIGHING SCALES Except EKO ...
Страница 26: ...25 WEIGHING SCALES EKO ...
Страница 33: ...32 COUNTING SCALES ...
Страница 129: ...ACHTUNG Nach Verlassen des Setup Menüs schalten Sie die Waage aus und wieder ein ...
Страница 135: ...UWAGA Po wyjściu z menu ustawień należy wyłączyć wagę i włączyć ją ponownie ...