Telular TG-1 Express Скачать руководство пользователя страница 26

56044702 17

 

© 2012 Telular Corporation 

check the signal strength. If the signal strength is OK, then call 
Technical Support. 

Important:

 In order to clear the faults listed above, the RSSI 

button must be pressed twice. After the issue has been 
resolved and the unit cleared, STEP 3 MUST BE REPEATED OR 
THE TELGUARD WILL NOT TRANSMIT ANY SIGNALS.  
 

System Status LEDs  

Activation Indications 

ALL LEDS FLASHING 

Failed Activation  – Signal Too 
Weak 

LED #1 & LED #4 FLASHING 

Activation Error – Call 
Telguard Technical Support 

LED #1 ON 

Activation Successful  

System Status LEDs Table 

 

If no LEDs besides the power LED are lit or flashing, it may 
indicate insufficient power supplied from the alarm panel. 
Press the RSSI button to change the LEDs to RSSI mode. If still 
no LEDs are lit, then check the voltage being supplied to the 
Telguard, and ensure that it is above 6.2V. 

 
 

Status LED #2 

Indication 

1 FLASH 

STC – Low Power Failure 

2 FLASH 

N/A 

3 FLASH 

N/A 

4 FLASH 

NSC – No Service 

5 FLASH 

RFC – Radio Failure 

6 FLASH 

DTF – Dial Tone Failure 

7 FLASH 

PPF – Panel Presence Failure 

System Trouble Condition, STC (LED #2) Table 

Содержание TG-1 Express

Страница 1: ...56044702 i 2012 Telular Corporation Installation Guide TG 1 Express June 21 2012 COMPANY CONFIDENTIAL For use by TELGUARD customers only Distribution to other parties strictly prohibited...

Страница 2: ...w telguard com Foreword The Telguard model TG 1 Express cellular alarm communicator is UL Listed for Household Fire systems and Household Burglary systems This means that the TG 1 Express may be used...

Страница 3: ...alarm panels The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable However Telular assumes no responsibility for inaccuracies an...

Страница 4: ...mplied If a Telguard unit needs to be returned for repair please return the product to the distributor that the unit was originally purchased from If you are unsure of the distributor please contact T...

Страница 5: ...rotected premises to a central monitoring station may be inoperable or temporarily out of service Cellular radio networks are also subject to compromise by sophisticated methods of attack This equipme...

Страница 6: ...e use and operation of the Product INDEMNIFICATION OF TELULAR CORPORATION TELULAR YOU SHALL INDEMNIFY DEFEND AND HOLD HARMLESS TELULAR FOR ANY OF THE COST INCLUDING REASONABLE ATTORNEYS FEES AND FROM...

Страница 7: ...L OR USED IN A MANNER OR ENVIRONMENT NOT SPECIFICALLY AUTHORIZED IN THIS MANUAL UNAUTHORIZED MODIFICATIONS VOID THIS WARRANTY NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES LIABILITY LIMITED...

Страница 8: ...First Look 2 Features 3 Operating Mode 3 Panel Supplied Power 4 Single Line Interface Cable SLIC 4 Multiple Alarm Format Support 4 Complete Supervision of Communication Path 5 Telguard Automatic Self...

Страница 9: ...d Measure Signal Strength RSSI 12 Step 3 Program Activate Transmit Alarms 16 Step 4 Connect the Supervisory Trip Output 21 Step 5 Connect and Test the Trip Input optional 23 Step 6 Complete the Telgua...

Страница 10: ...eformatting the alarm signal is routed over the telco line Public Switched Telephone Network PSTN to the appropriate alarm company central station for action In a typical alarm installation Telguard D...

Страница 11: ...r cellular service and a complete history of every Telguard unit s operating conditions These conditions include programming setup information alarm transmission information supervisory trouble inform...

Страница 12: ...summarizes the key features of the Telguard TG 1 Express Operating Mode The Telguard Digital TG 1 Express is a digital cellular transmission device that is installed at the protected premises to prov...

Страница 13: ...communicator should be used both of which utilize a battery backed up A C power source separate from the panel Single Line Interface Cable SLIC To further simplify installation the TG 1 Express can be...

Страница 14: ...llular communication path If the cellular communications path becomes inoperative the TG 1 Express generates a relay trip output that can be connected to a zone input of the host alarm panel and or us...

Страница 15: ...V supply circuit that provides dial tone to the alarm panel A Dial Tone Failure DTF is declared when the 30V supply drops to 20V or less while the alarm panel is on hook The STC LED will flash 6 times...

Страница 16: ...ability Although Telguard has the capability for a daily weekly or monthly automatic self test a separate feature is provided for determining the current operational status of every Telguard This feat...

Страница 17: ...e Telular Communications Center TCC Trips on catastrophic failure CF if all power is lost Trips on transmit disable command from the Communication Center This radio command disables only the Telguard...

Страница 18: ...tomer database located at the Telular Communication Center The database includes information about the customer account unit location and system test plan information Dealer Account Establishment Prio...

Страница 19: ...ng Telguard business hours The subscriber record is created and the Telguard device will be ready for activation Activation occurs automatically upon transmission of the first alarm signal Pre Install...

Страница 20: ...Installation Summary There are six steps in installing Telguard properly IF YOU DO NOT PROCEED IN THE ORDER AND MANNER PRESCRIBED YOU MAY NOT COMPLETE THE INSTALLATION IN THE TIME ALLOCATED These six...

Страница 21: ...egistration form during Telguard business hours Step 2 Locate Unit and Measure Signal Strength RSSI Locate Unit Pick a spot next to the alarm panel where you think the Telguard will be mounted and pla...

Страница 22: ...struction 3 Connect the other end of the cable to the RJ 45 jack on the TG 1 Express Reconnect the alarm panel s power supply and ensure that the PWR indicator LED 8 on the TG 1 Express is illuminated...

Страница 23: ...best RSSI indication obtainable Care should be taken to ensure that a large metal object such as a refrigerator or a metal cabinet is not located on the opposite side of the wall If moving the Telgua...

Страница 24: ...or remote antenna to achieve maximum signal strength Pick the place where the most LEDs up to four are lighted RSSI Value Illuminated LEDs RF dBm NO SVC LED 5 slow flash LED 4 2 off n a 1 LED 5 on LE...

Страница 25: ...the Telguard will transmit all of the parameters from the Telguard along with the information central station number and account code from the alarm panel Once this information is received the TCC wil...

Страница 26: ...ED 4 FLASHING Activation Error Call Telguard Technical Support LED 1 ON Activation Successful System Status LEDs Table If no LEDs besides the power LED are lit or flashing it may indicate insufficient...

Страница 27: ...d can be programmed using a line man s butt set connected to T R Test Points or a POTS phone connected to the RJ 45 jack where the alarm panel is normally connected Key Sequence Description Enters the...

Страница 28: ...e corresponding values 00 STC Relay Output Not Used 01 LPF 08 NSC 16 RFC 32 DTF 57 ALL 852 STC Trip Delay for NSC 1 30 seconds 2 60 seconds 3 3 minutes 4 10 minutes 5 20 minutes 6 30 minutes 7 45 minu...

Страница 29: ...tation operator Use a lineman s butt set in MONITOR MODE and connected to Telguard s T and R test pins to listen to communications between the alarm panel and Telguard After the panel has finished com...

Страница 30: ...a trip is declared The STC trip output can be used directly to activate a local signaling device provided that the trip output is not needed to trip the host control communicator at the same time If...

Страница 31: ...egy Reprogram Alarm Panel to Send Proper Code If necessary reprogram the alarm panel to send proper alarm code when tripped by the Telguard s supervisory output Program zone restoral as desired Check...

Страница 32: ...8 and wait for the confirmation tone 2 beeps Enter 1 to start the history display The STC LED will light for 3 seconds then each STC in the history log will be displayed as a series of flashes of the...

Страница 33: ...customized at installation time using an ordinary phone set or a lineman s butt set in a similar manner to other Telguard programming options The relevant POTS programming commands are Mem Loc Field...

Страница 34: ...ult notification will be sent to the central station Swinger Function The swinger function is designed to reduce the incidence of excessive messaging and alarms due to faulty equipment or installation...

Страница 35: ...e TG 1 Express either with the enclosure open or closed A notch in the rear opening of the enclosure is provided to allow better cable access Note that as with other Telguard products the RJ 45 cable...

Страница 36: ...bl e trouble conditions Normally Closed 24 hour trip zone input on host alarm panel Enables transmission of programmed supervisory trouble code see diagram or installation section 3 TRIP IN Trip input...

Страница 37: ...e Normal Operating Mode LED Symbol Color Showing Indication LED 1 Activation Green Solid On Unit is activated at the message center and enabled Off Unit not activated at the message center and disable...

Страница 38: ...SUPPORT Off TG 1 Express initialized On TG 1 Express is waiting for response from Telular Communication Center LED 5 Radio Green Short Flash 1 sec Radio receiving message Long Flash 2 sec Radio sendi...

Страница 39: ...5 slow flash LED 4 2 off n a 1 LED 5 on LED 4 2 off 111 dBm 1 LED 5 on LED 4 slow flash LED 3 2 off 110 dBm 2 LED 5 4 on LED 3 2 off 100 dBm 2 LED 5 4 on LED 3 slow flash LED 2 off 90 dBm Minimum sig...

Страница 40: ...rnal 30V supply circuit failure Return unit for repair on RMA PPF STC LED flashes 7 times No Yes Wait for PPF restoral Not Activated Activation LED 1 off Yes None Telguard will not function until unit...

Страница 41: ...45mA idle 150mA transmitting 17Vdc 38mA idle 124mA transmitting Digital Cellular Radio The Telguard TG 1 Express is a 3G radio that supports GSM GPRS and UMTS cellular protocols It is equipped with a...

Страница 42: ...M 850MHz Class 4 2 watts GSM 1900MHz Class 1 1 watt WCDMA 850 1900MHz Class 3 0 250 watts FCC ID N7NSL8080 Supplied Antenna Dipole Physical Size 5 6 H x 2 9 W x 1 3 D Shipping weight 1 1 lbs Operating...

Страница 43: ...NC antenna cable and mounting bracket The CTX 12 is required for all ACD and external antenna accessories ACD 12 12 feet of antenna cable and mounting bracket ACD 35 35 feet of low loss high performan...

Страница 44: ...ystem communicates with the alarm monitoring center using a robust and secure Telguard cellular communicator instead of a traditional landline Wireless protection is the most reliable form of security...