SETUP
Safe Operation Requirement
The Phonecell
®
SX5 must be either wall mounted or desk mounted and should not be operated
when any person is within 203 mm (8 inches) of the antenna.
Emergency Batteries
Install Batteries
1. Remove the battery access door screw located on the bottom of the unit
- see Figure 3
.
2. Press the battery access door tabs and remove the battery access door.
3. Install 4 “AA” alkaline batteries (not supplied)
- see Figure 3
.
4. Reinstall the battery access door using the screw.
5. To test the batteries, turn the AC/Battery switch to battery operation. After the test, turn the
switch back to AC unless you want to continue to operate from battery power.
- see Figure 4
.
NOTE:
The SX5 does not support rechargeable batteries.
Battery Operation
The unit will not automatically switch from AC to battery upon loss of AC power. The AC/Battery
switch must be changed manually
- see Figure 4
. Battery power will provide up to one hour of
standby and 30 minutes of talk time, depending on the SX5 model.
Phonecell
®
SX5T CDMA
1
User Manual
AC/Battery Switch
Figure 4 –
SX5 AC/Battery switch.
Battery Position
AC Position
WARNING!
Only “AA” alkaline batteries are to be used with the Phonecell
®
SX5.
Use of any other batteries may result in fire and/or other damage to the unit.
!
Battery
Access
Door
Battery Access
Door Screw
Figure 3 –
SX5 battery installation.