LCD DISPLAY

The LCD displays call, programming and signal strength information 

- see Figure 10

.

Received Signal Strength

The Received Signal Strength is displayed by the first 11 characters (from left to right) in the
Indicator Row

- see Figure 10

. Received signal strength can be displayed by either a direct

readout of the signal strength in dBm or a signal strength bar graph. This setting is programma-
ble. See the 

Phonecell SX4

P

 Programming 

section of this manual.

Direct Readout

displays the signal strength as "

-XXXdBm

", where 

XXX

refers to the signal

strength. The SX4

P

 monitors signal strength in the range of -110dBm to -48dBm, where -

110dBm indicates no signal and -48dBm indicates the strongest signal. The factory setting is
the Direct Readout Mode. 

Signal Strength Bar Graph

displays the signal strength as a series of solid block characters.

The stronger the signal, the more characters are displayed from left to right. To set Bar Graph
mode, see the 

Phonecell SX4

P

 User-Programming Commands 

section of this manual.

NOTE:

The 12th character (from left to right) is used as a separator only and does not provide 

information 

- see Figure 10

. A "

||

" character is displayed and is always displayed.

Call-Timer

The Call Timer icon appears when the SX4

P

 begins a connected phone call. The call timer

begins as all zeros and increments every subsequent second. The timer will roll over back to
0:00 after 99:59. When the handset is placed on-hook (ends call), the call timer stops and dis-
plays the accumulated call time for thirty seconds. The Call Timer icon is then turned off.
If the handset goes off-hook and a digit is pressed within the thirty second period, the call time
display will immediately turn blank. 

Figure 10 – 

Phonecell SX4

P

 LCD Display.

PM

- Indicates

programming

mode. Used

only in the

Programming

Mode.

CALL#

-

Indicates an

unanswered

call has

been

received.

Envelope

-

Indicates

receipt of new

voicemail. Used

only in the

Normal Mode.

Alert

- Indicates that

voicemail audible alert is

turned on. Used only in

the Normal Mode.

Call Timer

-

Indicates the time

(minutes and sec-

onds) of a call.

Used only in the

Normal Mode.

Dialed Digits Row

-

Displays dialed digits

from the keypad, as well

as incoming CalIer ID

information. Numeric 

digits from 0-9 are

included.

Received Signal Strength

- Displays the Received Signal

Strength in one of two modes:

Direct Readout

displays signal strength in a range of 

-110dBm (no signal) to -48dBm (strongest signal).

Signal Strength Bar Graph

displays signal strength as

a series of solid block characters. The stronger the sig-

nal, the more characters are displayed from left to right.

Battery

- Indicates that

the SX4

P

 is operating on

the internal batteries.

Used in all modes.

Cellular Service

Indicator -

Displays the 

cellular status of the unit:

N”

= No service

“A”

= Analog (AMPS) 

service

“D”

= Digital (TIA/EIA-136)

Service

In-Use Indicator -

Displays 

“U”

when

the unit is in use.

Indicator Row

Roam Indicator -

Displays 

“R”

when

in the roam mode.

Hands-Free

-

Indicates

hands-free

operation.

NEW

- Indicates

a change in

stored data.

Used only in the

Programming

Mode.

Содержание PHONECELL SX4P TDMA 800

Страница 1: ...11 04 03 Part Number 56027801 rev2 PHONECELL SX4P TDMA 800 DESKTOP PHONE VOICE MODEL USER MANUAL...

Страница 2: ...ission of your or your agents contractors servants employees or other users of the Product so long as the Product was obtained from you in the use and operation of the Product INDEMNIFICATION OF TELUL...

Страница 3: ...NECELL SX4P POWER UP SEQUENCE 7 PHONECELL SX4P NORMAL MODE 7 OPERATION 7 Phonecell SX4P Controls 7 Place a Call 8 Receive a Call 8 End a Call 8 Two Digit Dialing 8 Store a New Number in Memory 8 Use M...

Страница 4: ...battery access door screw located on the bottom of the unit see Figure 3 2 Press the battery access door tab and remove the battery access door see Figure 3 3 Install the batteries not included see Fi...

Страница 5: ...4 inches vertically apart and drill two holes into the wall 3 Install the screws not supplied into the wall leaving a gap approximately 3 mm 1 8 inches between the screw head and the wall 4 Align the...

Страница 6: ...handset is placed on hook ends call the call timer stops and dis plays the accumulated call time for thirty seconds The Call Timer icon is then turned off If the handset goes off hook and a digit is p...

Страница 7: ...by the cellu lar network If the service is not provided or the caller ID is blocked or unknown the display remains blank on incoming calls OPERATION Phonecell SX4P Controls Front Panel All controls f...

Страница 8: ...option NOTE If the call is ended by the other party the SX4P will clear the line and re establish a dial tone within 13 seconds The SX4P may then be used for another call or may be hung up Two Digit D...

Страница 9: ...ormal steady dial tone ROH Receiver Off Hook Tone If the SX4P handset remains off hook off its cradle with no dialing activity for 30 seconds the receiver emits an ROH tone for 45 seconds Incoming Cal...

Страница 10: ...ss of power to the SX4P verify proper connec tion to AC power If AC power is unavailable verify that the batteries are in good condition and that the battery switch is in the battery power active posi...

Страница 11: ...led Digits row 7 An incorrect entry causes the Dialed Digits row to flash When a numeric key is then pressed it causes The Dialed Digits row to turn off The NEW icon to remain displayed The pressed ke...

Страница 12: ...for direct readout in dBm or 1 for bar graph If the RSSI display type value is greater than 1 it is considered invalid The factory default is 1 LCD Display Contrast The following key sequence is used...

Страница 13: ...es cause harmful interference to radio or television reception which can be determined by turning the equipment OFF and ON the user is encouraged to to cor rect the interference by one or more of the...

Страница 14: ...WARRANTY CONDITIONS This is the complete warranty for the Products manufactured by Telular and sold to Buyer Telular assumes no obligation or liability for additions or modifications to this warranty...

Страница 15: ...SOFTWARE PROVISIONS Laws in the United States and other countries preserve for Telular certain exclusive rights for copyrighted Telular software such as the exclusive rights to reproduce in copies and...

Страница 16: ...lular Corporation all rights reserved Part Number 56027801 rev2 647 North Lakeview Parkway Vernon Hills Illinois 60061 USA Tel 847 247 9400 Fax 847 247 0021 E mail mainoffice telular com http www telu...

Отзывы: