Telular PHONECELL SX4P TDMA 800 Скачать руководство пользователя страница 13

PGENERAL INFORMATION AND SAFETY

Temperature Environment

The SX4

P

 functions as both a radio transmitter and receiver. When it is ON, the SX4

P

 receives and

sends radio frequency (

RF) 

energy. The SX4

P

 operates in the frequency range of 824 MHz to 894

MHz. It employs commonly used phase/frequency modulation techniques. When you use the SX4

P

,

the cellular system handling your call controls the power level at which your unit transmits. 

Operating Temperature:

From -10°C (14°F) to +50°C (122°F); Up to 95% relative humidity (non-condensing)

Storage Temperature:

From -20°C (-4°F) to +60°C (140°F); Up to 95% relative humidity (non-condensing)

Exposure to RF (Radio Frequency) Energy

In 1991, the Institute of Electrical and Electronics Engineers (IEEE), and in 1992, the American
National Standards Institute (ANSI), updated the 1982 ANSI Standard for safety levels with respect to
human exposure to RF energy. After reviewing the available body of research, more than 120 scien-
tists, engineers and physicians from universities, government health agencies and industry developed
this updated Standard. In March, 1993, the U.S. Federal Communications Commission (FCC) pro-
posed the adoption of this updated Standard.
The design of your Telular Phonecell SX4

P

 complies with this updated Standard. If you want to limit

RF exposure even further than the updated ANSI Standard, you may choose to control the duration of
your calls and operate your phone in the most power-efficient manner.

FCC Part 15 Class B Compliance

The SX4

P

 model has been tested and found to comply with the limits for a Class B digital device, pursuant to

Part 15 of the FCC rules. Changes or modifications not expressly approved by Telular Corporation will void
your authority to operate the equipment per FCC part 15 paragraph 15.21. These limits are designed to pro-
vide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to to cor-
rect the interference by one or more of the following measures:
•  Reorient or relocate the antenna.
•  Increase the separation between the equipment and the terminal
• Connect the equipment into an outlet on a circuit different from that to which the terminal is connected.
• Consult your Authorized Telular Distributor or an experienced radio/TV technician for help.

Safe Operation Requirements

Antenna Care and Replacement

•  The Phonecell must be either wall mounted or desk mounted and should not be operated when any person

is within 203 mm (8 inches) of the antenna.

•  Attach either a lightning arrester or a ground wire on the antenna mast to an 8-foot ground rod or cold water

pipe.

•  Do not use the Phonecell with a damaged antenna. If a damaged antenna comes into contact with the skin,

a minor burn may result. Have your antenna replaced by a qualified technician immediately.

•  Do not power unit until antenna is connected, as it may burn out the radio transmitter.
•  Use only a manufacturer-approved antenna. Unauthorized antennas, modifications, or attachments could

damage the Phonecell and will void the Grant of Type Acceptance.

•  Your Phonecell SX4

P

 must be placed or mounted on a flat surface to allow proper ventilation. Do not block

the air vents or the space beneath your Phonecell SX4

P

 as this could cause the unit to overheat and fail.

Interference to Medical and Personal Electronic Devices

• Do not use the Phonecell SX4

P

 in health care facilities when any regulations posted in the

area restrict cellular phone use.

NOTE:

Consult the manufacturer(s) of your medical and personal electronic device(s) (for example a

pacemaker or hearing aid) to determine if they are adequately shielded from external RF energy. Your

physician may be able to assist you in obtaining this information regarding medical devices.

CAUTION:

When cleaning, do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.

WARNING:

Potentially Explosive Atmospheres

• Do not operate the Phonecell near blasting caps or in a blasting area.
• Do not install the Phonecell in any area with potentially explosive atmosphere.
• Do not transport or store flammable gas, liquid or explosives in the area of your Phonecell or accessories.

Phonecell SX4

P

 TDMA 800 

13 

User Manual

Содержание PHONECELL SX4P TDMA 800

Страница 1: ...11 04 03 Part Number 56027801 rev2 PHONECELL SX4P TDMA 800 DESKTOP PHONE VOICE MODEL USER MANUAL...

Страница 2: ...ission of your or your agents contractors servants employees or other users of the Product so long as the Product was obtained from you in the use and operation of the Product INDEMNIFICATION OF TELUL...

Страница 3: ...NECELL SX4P POWER UP SEQUENCE 7 PHONECELL SX4P NORMAL MODE 7 OPERATION 7 Phonecell SX4P Controls 7 Place a Call 8 Receive a Call 8 End a Call 8 Two Digit Dialing 8 Store a New Number in Memory 8 Use M...

Страница 4: ...battery access door screw located on the bottom of the unit see Figure 3 2 Press the battery access door tab and remove the battery access door see Figure 3 3 Install the batteries not included see Fi...

Страница 5: ...4 inches vertically apart and drill two holes into the wall 3 Install the screws not supplied into the wall leaving a gap approximately 3 mm 1 8 inches between the screw head and the wall 4 Align the...

Страница 6: ...handset is placed on hook ends call the call timer stops and dis plays the accumulated call time for thirty seconds The Call Timer icon is then turned off If the handset goes off hook and a digit is p...

Страница 7: ...by the cellu lar network If the service is not provided or the caller ID is blocked or unknown the display remains blank on incoming calls OPERATION Phonecell SX4P Controls Front Panel All controls f...

Страница 8: ...option NOTE If the call is ended by the other party the SX4P will clear the line and re establish a dial tone within 13 seconds The SX4P may then be used for another call or may be hung up Two Digit D...

Страница 9: ...ormal steady dial tone ROH Receiver Off Hook Tone If the SX4P handset remains off hook off its cradle with no dialing activity for 30 seconds the receiver emits an ROH tone for 45 seconds Incoming Cal...

Страница 10: ...ss of power to the SX4P verify proper connec tion to AC power If AC power is unavailable verify that the batteries are in good condition and that the battery switch is in the battery power active posi...

Страница 11: ...led Digits row 7 An incorrect entry causes the Dialed Digits row to flash When a numeric key is then pressed it causes The Dialed Digits row to turn off The NEW icon to remain displayed The pressed ke...

Страница 12: ...for direct readout in dBm or 1 for bar graph If the RSSI display type value is greater than 1 it is considered invalid The factory default is 1 LCD Display Contrast The following key sequence is used...

Страница 13: ...es cause harmful interference to radio or television reception which can be determined by turning the equipment OFF and ON the user is encouraged to to cor rect the interference by one or more of the...

Страница 14: ...WARRANTY CONDITIONS This is the complete warranty for the Products manufactured by Telular and sold to Buyer Telular assumes no obligation or liability for additions or modifications to this warranty...

Страница 15: ...SOFTWARE PROVISIONS Laws in the United States and other countries preserve for Telular certain exclusive rights for copyrighted Telular software such as the exclusive rights to reproduce in copies and...

Страница 16: ...lular Corporation all rights reserved Part Number 56027801 rev2 647 North Lakeview Parkway Vernon Hills Illinois 60061 USA Tel 847 247 9400 Fax 847 247 0021 E mail mainoffice telular com http www telu...

Отзывы: