Installation
Page 2-16
Power-Up and
Verification
Apply commercial power to the unit and observe the front panel indicators. After
several seconds, the Power indicator should illuminate. The unit displays different
conditions depending on the NET-PATH internal programming. The usual event
sequence follows.
1
The Status indicator flashes while the unit is initializing
2
After the unit initializes, the Battery indicator illuminates. This indicator is on
when the battery is fully charged and flashes when the battery is charging.
3
The NET-PATH displays the
internal device libraries on the bottom line of the
LCD display as the database loads. The Alarm LED flashes twice – once at the
beginning of the database loading process and once at the conclusion of the
process.
4
After a successful power-up, the NET-PATH LCD display panel displays a
banner, the software Program Update Number (PUN), an off-hook indicator
(OH: Y/N), and the current date and time.
Figure 2-21 NET-PATH LCD Display
22
The indicators for Power, Battery, and Status illuminate. The battery indicator
may flash to indicate that the battery is charging.
23
If the Status indicator does not illuminate, the NET-PATH does not have a valid
database loaded. Contact your network system administrator at the Polling and
Analysis Center.
Internal Battery
Test
To perform an internal battery test
1
Confirm that the internal battery is operating properly.
2
While the unit power is on, unplug the NET-PATH’s power cord.
3
Verify the Status and Battery indicators are on and the Power indicator is off.
4
Restore commercial power to the NET-PATH and verify the Power, Status, and
Battery indicators are on.
5
The Battery LED flashes to indicate the battery is charging.
Functional
Verification
Verify that the NET-PATH can receive calls by initiating calls from the Polling and
Analysis Center. If you can call the NET-PATH, it is ready for operation. Should
problems occur during the NET-PATH installation, refer to "Troubleshooting"‚ page
4-11 for troubleshooting procedures.
If the NET-PATH contains an international modem, you must enter the country code
before the modem can function. "Country Code Definitions for Multi-Tech Modem
Model MT5634SMI"‚ page 4-6.
Содержание SEB NET-PATH
Страница 1: ...SEB NET PATH Installation and Operation Guide ...
Страница 2: ......
Страница 3: ...SEB NET PATH Installation and Operation Guide ...
Страница 6: ......
Страница 18: ...Preface xii Notes ...
Страница 24: ...Description and Specifications Page 1 6 Notes ...
Страница 42: ...Installation Page 2 18 Notes ...
Страница 58: ...Operation Page 3 16 Note ...
Страница 80: ...Index I 4 Notes ...
Страница 81: ......