64
8.4.12
SMS data sending settings (ID=1250)
Parameter allows or does not allow sending AVL data using binary SMS. If SMS use is not
allowed value is 0 and 1 if SMS use is allowed.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
S8
8.4.13
SMS Data send week time schedule (ID=1273)
Parameter defines SMS data sending according to week time schedule. This parameter is
used to set data sending on selected week days and hours. Minimum time step is 10 minutes.
Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF
For more information
read 8.5.1.4 “Schedule parameter format”.
8.4.14
Authorized phone numbers (ID=1260-1270)
If at least one number is entered then only those number can send messages to device.
Number must be entered without “+” or “00”.
Example: 37060012346
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1 digit
16 digits
-
S8[17]
If SMS data sending is enabled (ID=1250) first value in a list is server GSM number. The SMS with
24 coordinates is sent to this number.
Deleting Authorized phone numbers:
do no write any value is configuration SMS command.
Example: setparam 1260
8.4.15
SMS Event PreDefined Numbers (ID=150-159)
In this field are written GSM numbers, to which will be sent “Event SMS” text message.
Number must be entered without “+” or “00”.
Example: 37060012346
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1 digit
16 digits
-
S8[17]
8.4.16
Operator List (ID=1271 X)
Parameter defines operator list. According to this list module selects operating profile.
GSM operator codes are comma separated. First in a list is
Home Operator Code
, then Preferred
Roaming Operator Codes are written.
X defines starting position that is changed: If X is from 0 to 49, X means index of operator
code which has to be configured. Up to 20 operator codes may be configured in 1 SMS. Example:
s
etparam 1271 16 24602,24603,24605