48
Figure 45 I/O event configuration
Figure 46 I/O SMS event configuration
5.15
I/O settings
When no I/O element is enabled, AVL packet comes with GNSS information only. After
enabling I/O element(s) AVL packet along with GNSS information contains current value(s) of
enabled I/O element.
Permanent I/O elements
(are always sent to server if enabled)
Nr.
Property Name
Description
0
Digital Input Status 1
Logic: 0 / 1
1
Digital Input Status 2
Logic: 0 / 1
2
Analog Input 1
Voltage: mV, 0 – 30 V
3
Digital Output 1
Logic: 0 / 1
4
Digital Output 2
Logic: 0 / 1
5
GNSS PDOP
Probability * 10; 0-500
6
GNSS HDOP
Probability * 10; 0-500
7
External Voltage
Voltage: mV, 0 – 30 V
8
GNSS Power
States: 0 – short circ., 1 – connected.
Parameter defines if GNSS antenna is short circuit.
All the time value will be sent 1. The only condition
to get value 0, then antenna is damaged and short
circuit. Note if you disconnect GNSS antenna it still
will be sent 1. Do not try to use this parameter to see
if antenna is disconnected.
9
Movement Sensor
0 – not moving, 1 – moving.
10
Odometer Value
Distance between two records: m
11
GSM Operator
Currently used GSM Operator code
Содержание FM3600