![Teltonika FM1110 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/teltonika/fm1110/fm1110_user-manual_1084738016.webp)
16
3.7
Accessories
Note: Teltonika does not provide any additional equipment like panic buttons,
door sensors or others.
1 – Wire devices
One of the realized features FM1110 is 1-Wire® data protocol, which enables connection
of thermometer (DS1820, DS18S20 and DS18B20) and I-Button type:
DS1990A
(Figures 8 and 9
show FM1110 and 1-wire® device connection schemes).
Left row of pins
1
3
4
1
2
2
J1
J2
J3
U1
Right row of pins
1W. PWR
(FM1110 – pin10)
1
1W. Data
(FM1110 – pin8)
2
1
Vpp (+5 Volts DC) –
power source for
external digital
sensor
GND
(FM1110 – pin6)
3
2
Output from external
digital sensor
Digital Input
4
Figure 8 Digital thermometer DS1820 and TTJ100 connection scheme
Downloaded from
www.Manualslib.com
manuals search engine