![Teltonika FM1010 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/teltonika/fm1010/fm1010_user-manual_1084730058.webp)
58
value
value
value
parameters
type
0
2592000
-
GPRS Week Time (ID=1575)
U32
8.5..20
GPRS Week Time (ID=1575)
Read chapter 8.5..4.
Unknown Network GSM operator code “Vehicle on STOP” parameters
8.5..21
Min Period (ID=1580)
This parameter indicates time interval in seconds in order to acquire new record. If value is
0 it means no records by min period will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
U32
8.5..22
Min Saved Records (ID=1583)
This parameter defines minimum number of records in one data packet that can be sent to
server. It has higher priority than Data Send Period (ID=1584).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
255
1
U8
8.5..23
Send Period (ID=1584)
This parameter indicates frequency (time interval in seconds) of sending data to server.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
U32
8.5..24
GPRS Week Time (ID=1585)
Read chapter 8.5..4.
Unknown Network GSM operator code “Vehicle MOVING” parameters
8.5..25
Min Period (ID=1590)
This parameter indicates time interval in seconds in order to acquire new record. If value is
0 it means no records by min period will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
U32
8.5..26
Min Distance (ID=1591)
This parameter indicates distance in meters in order to acquire new record. Record is
stored when the distance between previous records is greater than parameter’s value. If value is
0 it means no records by min distance will be saved.