54
Example: 37060012346
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1 digit
16 digits
-
S8[17]
If SMS data sending is enabled (ID=1250) first value in a list is server GSM number. The SMS with
panic priority will be sent
SMS Event PreDefined Numbers (ID=150-159)
In this field are written GSM numbers, to which will be sent “Event SMS” text message.
Number must be entered without “+” or “00”.
Example: 37060012346
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1 digit
16 digits
-
S8[17]
8.5
Data Acquisition Modes parameters
Home Network GSM operator code “Vehicle on STOP” parameters
8.5..1
Min Period (ID=1540)
This parameter indicates time interval in seconds in order to acquire new record. If value is
0 it means no records by min period will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
U32
8.5..2
Min Saved Records (ID=1543)
This parameter defines minimum number of records in one data packet that can be sent to
server. It has higher priority than Data Send Period (ID=1544).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
255
1
U8
8.5..3
Send Period (ID=1544)
This parameter indicates frequency (time interval in seconds) of sending data to server.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
Min Saved Records (ID=1543)
U32
8.5..4
GPRS Week Time (ID=1545)
This parameter manages when it is allowed to open GPRS context. When module starts it is
prohibited to open the context. When modem’s GPRS context is closing (for example changing
network) it is allowed to open it only at a defined time. It is possible to allow connections every