![Teltonika FM1010 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/teltonika/fm1010/fm1010_user-manual_1084730050.webp)
50
Sleep timeout (ID=1001)
Sleep timeout is time after which FM1010 goes to sleep or deep sleep if other
requirements are met. It is measured in minutes.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
3000
-
U8
Mode Switch Source (ID=1002)
Device can operate and change its working mode according to motion detection source:
ignition (value 0), movement (value 1), GNSS (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
Ignition Source (ID=1003)
Device can operate and change its working mode according to motion detection source:
Power Voltage (value 0), Digital Input 1 (value 1), movement (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
Power Voltage Low Level (ID=1006)
Power Voltage Level High Level
(1007)
U8
Saving/Sending without time synchronization (ID=1005)
When this feature is enabled (value = 1), then records can be saved and sent to server
without time synchronization.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
U8
Power Voltage Low Level (ID=1006)
When ignition source is selected as Power Voltage Low level for ignition detection must be
set.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
30000
-
Ignition Source (ID=1003)
Power Voltage Level High Level
(1007)
U16
Power Voltage High Level (ID=1007)
When ignition source is selected as Power Voltage High level for ignition detection must be
set.
Minimum Maximum Recommended
Goes with (depends on)
Value
Содержание FM1010