Voice Gateway 4FXS User Manual
- 81 -
values in the Flash or memory as the current configured values. For example:
system> load pf2
Testing command
system> test {parameter}
The parameter only can be ring, connect, playtone {parameter}, loop or
gr909{ parameter }. Therein, the parameter of playtone only can be Silence, dial,
ringback, busy, callwaiting or howler; and the parameter of gr909 is Channel No.
system> timezone
This command is set by way of interaction, and does not need any parameter. After
carrying out the command, CLI will display the time zone set currently and require
new time zone to be entered. Negative number means east time zone, positive
number means west time zone. For example, China locates at east time zone 8, UTC
offset [-8].
During setting, users button enter key to keep the original port settings, and button
“Ctrl + C” to cancel the setting.
Command to display software and hardware version numbers
system> version
It has no need of any parameter. After the command is performed, CLI will display the
following information:
Hardware Version: … …
Software Version: … …
Created Time: … …
“Hardware Version” and “Software Version” refer to the version number of
hardware and software respectively, and “Created Time” refers to the software
compilation time.