background image

21

  |  Section 4

Simple Setup Page 

The Simple Setup Page allows for quick and easy selection of sources and destinations, along with setting the 
xNode’s ID. 

Figure 21   Simple Setup page

Node ID:

At the top of the Simple Setup page, the ID of the SDI xNode can be set, along with forcing the unit’s host name to 
the Node ID, and the channel numbers for the sources to match that of the Node ID.  

Sources 

Sources define the audio inputs of the xNode coming from the SDI Input(s).  An input of the xNode is given a 
name and a unique channel number that is used to distribute through the AoIP network.

Destinations 

The Destination page defines the audio outputs of the xNode.  These are streams coming from the AoIP network to 
be embedded in the SDI output(s).

Содержание Linear Acoustic SDI XNODE

Страница 1: ...LINEAR ACOUSTIC SDI XNODE Livewire AES67 Audio over IP Interface with Dual HD SD SDI Ports USER S MANUAL Manual for software version 1 6 4e January 2019 TelosAlliance com...

Страница 2: ...k an easily accessible safety disconnect device should be included in the rack design To reduce the risk of electrical shock do not expose this product to rain or moisture This unit is for indoor use...

Страница 3: ...Alliance which are mentioned in this manual or accompanying material are informational only The Telos Alliance makes no endorsement of any particular product for any purpose nor claims any responsibil...

Страница 4: ...on number which must be written on the exterior of your shipping container Please do not include cables or accessories unless specifically requested by the Technical Support Engineer Be sure to adequa...

Страница 5: ...6 Connections 6 Rear Panel 6 AC Power Connection 7 Backup Power Connection 7 Network Connections 7 SDI Input 7 SDI Output 7 Installation and Mounting 7 Installation 7 Mounting 7 Rack Mount kit 8 Fron...

Страница 6: ...actory Reset Restoring Defaults 18 4 WebInterface 19 Interface 19 System Option Pages 19 Home Page 19 Simple Setup Page 21 Unicast Link Page 22 Advanced Options Pages 25 Sources Page 25 Destination Pa...

Страница 7: ...ontents 6 ConfigurationExample 39 Introduction 39 SDI In to Livewire Source 40 Livewire Destinations 42 SDI Output Embedding 43 7 Specifications 44 Physical 44 Electrical 45 Audio 46 Other 46 8 TelosA...

Страница 8: ......

Страница 9: ...nspire our customers to create the most exciting and engaging audio experiences imaginable We re grateful that you have chosen audio tools from Telos Systems Omnia Audio Axia Audio Linear Acoustic 25...

Страница 10: ...es up to 16 channels of audio to the Livewire network called a Livewire Source and receives up to 16 channels of audio from the Livewire network Livewire Destination xNode Family The xNodes are a fami...

Страница 11: ...world s only zero configuration Ethernet switch optimized for Livewire Features eight 8 100BT Ethernet ports along with two 2 1000BT ports for trunking 1000BT ports include both RJ 45 and SFP fiber c...

Страница 12: ...3 Section 1 Warranty and Feedback For the latest Telos Alliance warranty visit telosalliance com warranty...

Страница 13: ...r cord style matches country of order Quick start sheet to get you up and running USB memory stick containing documentation including this manual rack mount hardware kit a handy black pen Unit Overvie...

Страница 14: ...the SDI xNode you will find OLED display Two pushbutton switches for Display page selection Screen button Edit Mode selection Pencil button Power LED The OLED display provides the user with visual fee...

Страница 15: ...xNode is where all connections are made The rear panel includes Power inlets Two 100 BT Ethernet ports Two 75 ohm BNC connectors for SDI inputs Two 75 ohm BNC connectors for SDI outputs Connections T...

Страница 16: ...All 16 channels of an SDI stream are available for de embedding embedding and pair shuffling SDI Output Two SD HD SDI output connections are included on the rear of the SDI xNode All 16 audio channel...

Страница 17: ...ns two short rack ears one long rack ear and a spacer plate Figure 5 Short rack mount ears Figure 6 Long rack mount ear Single xNode To rack mount a single xNode secure the short rack ear to one side...

Страница 18: ...de To mount two units side by side Remove the top lid from both xNodes Place two xNodes side by side Place the spacer plate between the two xNodes Figure 8 Spacer plate in between two xNodes top view...

Страница 19: ...of the power source s applied to the SDI xNode Color Description Green Powered by the primary AC Mains power supply IEC inlet Yellow Powered by both AC Mains and redundant power input Red Powered by...

Страница 20: ...rces 1 4 are shown on the left and Destina tions 1 4 are shown on the right Figure 11 Meters for I O pairs 1 4 Audio Meters Source Destination 5 8 Audio meters for Sources 5 8 and Destinations 5 8 are...

Страница 21: ...atus information regarding the input status and video format and frame rate of the input signal Figure 13 SDI input status screen xNode ID Screen The Node number source channel numbers and IP address...

Страница 22: ...13 Section 2 IP Address and Subnet Mask The IP address Subnet Mask and status of active network ports are displayed on this screen Figure 15 IP configuration screen...

Страница 23: ...u a Node ID with no value Channel numbers 1 8 and no IP address shown in Press the second button pencil icon for 10 seconds to enter into edit mode Figure 16 Front Panel Display With the cursor shown...

Страница 24: ...ll appear with a list of sources that are present on the network A sample of three xNodes freshly installed into a network is shown in Figure 17 At this point not many sources have been configured wit...

Страница 25: ...same IP address by pressing the increment button when the IP address is highlighted in the Node ID page This will toggle between a custom address or the new address created though the auto configurati...

Страница 26: ...as been assigned an ID value the device has an IP address that can be used to access its HTML configuration interface Each input has been assigned a unique Livewire channel number The next configurati...

Страница 27: ...The initial page is the Home page Select the Simple setup button In the Sources section you will provide a name value to help identify the audio source in network advertisements If a unique ID was as...

Страница 28: ...user name and password in order to prevent unauthorized or unintended changes during normal operation Note The default login details for the SDI xNode are Username user all lower case letters Password...

Страница 29: ...emperature Thetemperaturereadingfromtheinternalsensor Alarmstatuswillappearifthetemperatureisaboveacceptablelimits Sync A solid Sync indication represents synchronization with the network Net1 and Net...

Страница 30: ...forcing the unit s host name to the Node ID and the channel numbers for the sources to match that of the Node ID Sources Sources define the audio inputs of the xNode coming from the SDI Input s An in...

Страница 31: ...k is Real Time Streaming Protocol RTSP which is a TCP IP protocol Audio is sent using unicast UDP IP protocol Basic Setup The most basic setup involves setting one xNode as Passive This is also the de...

Страница 32: ...the connection is successful the icons turn green and Stream active RTSP OK status is displayed Custom Setup In order to limit number of channels set Stream Mode to Disabled on the Sources page Figur...

Страница 33: ...lave which allows for a higher packet forwarding jitter This setting can be changed on the QoS WEB page Unicast Status on xNode Front Panel In Unicast mode the front panel presents the link status inf...

Страница 34: ...e based on the ID given to the xNode It is critical that each source in the network has a unique number not shared with any other source Stream Mode Stream mode column defines the source as a stereo s...

Страница 35: ...ent of 12dB Mode The Mode column defines whether the input audio is synchronous to the Livewire network master clock or uses a different clock reference and Sample Rate Converters are inserted on the...

Страница 36: ...rmation in the text field but the change will not take place until the Apply button is pressed Selecting some To source from the network will automatically change the type field for you Type The Type...

Страница 37: ...bi directional backfeed link Surround Front L R Selects an 8 channel multichannel output This option is only available out at destination number 1 and 4 and links the following 3 destination pairs to...

Страница 38: ...tput stream are available for embedding pair shuffling and pass through Out This column represents the audio channels of the output SDI stream The signal source to be embedded into the SDI output will...

Страница 39: ...nsure synchroni zation between audio and video signals at the SDI output The delay may be adjusted in both milliseconds ms and in microseconds us increments Up to a full second of video delay for each...

Страница 40: ...etwork Livewire IP STL is an option for an application where a node is at the remote end of an STL link Live streams not supported while in this mode Livewire IP high rate tasks the node to synchroniz...

Страница 41: ...other A domain association is used to define communication messages A value of 0 is standard PTP delay mechanism E2E or P2P PTP supports two methods of time correction which alter messaging between de...

Страница 42: ...and will need to connect to the device with the new IP address you just assigned You may also configure a management port By default NET2 address will be assigned to 0 0 0 0 which defines the second p...

Страница 43: ...Community Name Define the community for SNMP functionality Syslog Server IP address of the computer which is running a syslog server application Syslog Severity Level Filter The 8 standard syslog leve...

Страница 44: ...liant with the standard supporting interoperability with third party devices In particular the following features are implemented Multicast and Unicast Real Time Protocol RTP audio streaming Session I...

Страница 45: ...choice over devices with a higher number The range is 0 255 and 128 is the default and middle value PTP clock sync interval determines how often clock packets are sent The faster those packets are sen...

Страница 46: ...n and IP address of the node xNodes provide the stream addresses on the Sources WEB page so that you can conveniently copy them In Unicast mode Source accepts SIP connections There are a few possible...

Страница 47: ...the current status If no triangle is shown the Source and Destination port is not configured for Unicast If the triangle is blinking the port is configured for Unicast but there is no active connectio...

Страница 48: ...SDI stream on SDI Input 1 that contains three audio programs a main stereo program in English a stereo program in a second language SAP a 5 1 channel program for the High Definition channel The audio...

Страница 49: ...ignal Type 1 1 2 Stereo Program English PCM 2 3 4 5 1 ch program L R PCM 3 5 6 5 1 ch program C LFE PCM 4 7 8 5 1 ch program Ls Rs PCM 5 9 10 Stereo Program SAP PCM 6 11 12 Not used PCM 7 13 14 Not us...

Страница 50: ...41 Section 6 Figure 41 Sources Configuration...

Страница 51: ...usingtheDestinations page In this example we will configure Destination 1 as coming from AERO soft 1 1 the 5 1 ch processor Destina tion 2 as coming from AERO soft 1 2 the first 2 channel processor an...

Страница 52: ...o program English is embedded in SDI pair 1 The stereo program SAP is embedded into SDI pair 5 The 5 1 channel program is embedded into SDI pairs 2 3 and 4 Of course the audio signals presented at the...

Страница 53: ...degrees C Non operating 20 70 degrees C User Interface Display dot matrix single color OLED display Front Panel Control Two multi function push button switches Web Control Internal http server Enable...

Страница 54: ...mination via BNC F connectors Auto sensing 3GHz HD SD SDI with de embedding of audio channels from each SDI input De embedded audio can be routed to Livewire output and or re embedded to its matching...

Страница 55: ...r a Class A digital device pursuant to Part 15 of the FCC rules CFR Europe Designed to comply with the limits of harmonised Low Voltage Directive 2006 95 EC and EMC Directive 2004 108 EC as indicated...

Страница 56: ...Telos Alliance Limited Warranty For the latest Telos Alliance warranty visit telosalliance com warranty...

Страница 57: ......

Страница 58: ......

Страница 59: ......

Страница 60: ...1241 Superior Ave Cleveland Ohio 44114 USA 1 216 241 7225 TelosAlliance com 2019 TLS Corp Linear Acoustic The Telos Alliance All Rights Reserved L19 1 18099...

Отзывы: