![Tellus Power UP80J Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/tellus-power/up80j/up80j_installation-manual_1084149009.webp)
!
Station
Housing
Station
Head
Chassis
PEM nut
Mounted
Housing
Station
Head Unit
Grounding
Strap
Grounding
Strap
Level-2 Charging
Coupler(s)
Strain Relief
Loop
When attaching the grounding strap to the housing ensure that
the spring washer is completely compressed and that the
hardware is in the following order:
Bolt
Flat Washer
Strap
Spring washer
Head Chassis with embedded PEM nut
Unpack the Station Head., Lay it on a soft surface
near the station housing and unravel the charg-
ing cable(s).
Thread the level-2 coupler(s) downwards though
the black rubber strain relief loop near the base
of the station housing post. Pull most of the
cable(s) through.
Loosen the grounding strap hardware at the free
end of the strap. Check that the hardware order
is as shown below.
Insert the charging head into the mounted
housing post. The bottom of the station head
slides into the base plate slot.
Rotate the head up towards the housing post and
connect the free end of the grounding strap to
the housing. Tighten!
Insert Head
Grounding Strap Connections
Page 9
Station Head Installation and Grounding:
9A
9B
KIT301-IM-20140501