PAN11-1B/-2B/-3B/-5B/-8B 

Smart energy plug in switch

 

P

     

 

 

This  plug-in  ON/OFF  switch  PAN11  is  a  security  enabled  wireless  switch,  based  on 
Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the  Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of 

the  connected  load  is  possible  with  other  manufacturer’s  wireless  Controller.  Each 
switch  is  designed  to  act  as  a  repeater.  Repeaters  will  re-transmit  the  RF  signal  to 
ensure  that  the  signal  is  received  by  its  intended  destination  by  routing  the  signal 
around obstacles and radio dead spots. Because PAN11 supports Security Command 
Class, it can  learn  with Secured controller. Its functionality and supported command 
classes is identical when included as a secure and non-secure device. 
 
This  plug-in  ON/OFF  switch  is  able  to  detect  instance  wattage  (3000W/CE/CN, 
1500W/UL/TW/JP)  and  overload  current  (14.5A)  of  connected  lights  or  appliances. 
When detecting overload state, the Switch will be disabled and its On/Off button will 
be  lockout  of  which  LED  will  flash  quickly.    However,  unplug  and  re-connect  the 
switch will reset its overload condition to normal status. 
 

Adding to Z-Wave

TM

 Network

 

 
In the front casing, there is an On/Off button with LED indicator which is used to toggle 
switch  on  and  off  or  carry  out  inclusion,  exclusion,  reset  or  association.  When  first 
power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second 

intervals. It implies that it has not been assigned a node ID and start auto inclusion.   
 
Auto Inclusion 
 
The function of auto inclusion will be executed as long as the switch does not have 
Node ID and just plug the switch into a wall outlet. 
 
Note:
 Auto inclusion timeout is 2 minute during which the node information of explorer 
frame will be emitted once several seconds. Unlike “inclusion” function as shown in 
the table below, the execution of auto inclusion is free from pressing the On/Off button 
on the Switch. 
 
The table below lists an operation summary of basic Z-Wave functions. Please refer to 
the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the Setup 

function, and to include/exclude/associate devices 
 

Function 

Description 

Annotation 

No node ID 

The Z-Wave Controller does not allocate 
a node ID to the Switch. 

LED 2-second on, 
2-second off 

Inclusion 

1.  Put your Z-Wave controller into 

inclusion mode by following the 
instructions provided by the 
controller manufacturer. 

 

2.    Pressing On/Off button three times 

within 2 seconds will enter inclusion 
mode.

 

Exclusion 

1.  Put your Z-Wave controller into 

exclusion mode by following the 
instructions provided by the 
controller manufacturer. 

 

2.  Pressing On/Off button three times 

within 2 seconds will enter exclusion 
mode. 

Node ID has been excluded. 

LED 0.5s On, 0.5s Off 
(Enter auto inclusion) 

Reset 

1.  Pressing On/Off button three times 

within 2 seconds will enter inclusion 
mode. 

Use this procedure only in 
the event that the primary 
controller is lost or 
otherwise inoperable. 

2.  Within 1 second, press On/Off 

button again for 5 seconds. 

Содержание PAN11-1B

Страница 1: ...lashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be e...

Страница 2: ...the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do no...

Страница 3: ...ommand Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consu...

Страница 4: ...ge V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report...

Страница 5: ...eport its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold...

Страница 6: ...On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update o...

Страница 7: ...sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU CN PAN11 1B 2B 3B 8B 908 40MHz 916 00MHz UL 922 927MHz TW JP PAN11 5B Specifications are subject to change and improvement w...

Страница 8: ...ng antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an...

Отзывы: