background image

 

 

 

 

 

 

 

Note

Please make sure that the intensity of the plug of the electrical device must be 

16A and have same head as the enclosed plug before inserting to the socket. 

 

 

Troubleshooting 
                                 

 

Symptom 

Cause of Failure 

Recommendation 

The Switch not working and 
LED off 

1.  The Switch is not 

plugged into the 
electrical outlet 
properly 

2.  The Switch break down 

1.  Check power connections 
2. Don’t open up the Switch and 

send it for repair. 

The Switch LED 
illuminating, but cannot 
control the ON/OFF 
Switch of the load attached 

1.Check if the load 

plugged into the Switch 
has its own ON/OFF 
switch 

2. The switch is protected 

1. Set the ON/OFF switch of the 

load attached to ON 

2. Unprotected the switch or follow 

the instruction of protection. 

The Switch LED 
illuminating, but the 
Detector cannot control 
the Switch 

1. Not carry out 

association 

2. Same frequency 

interference 

1. Carry out association 
2. Wait for a while to re-try 

LED keep flashing, but 
cannot control 

Overload occurs 

Remove the load attached or 
check max. load cannot exceed 
13.0A

 

 

Specification 
 

Operating Voltage 

230V/50Hz 

Maximum Load 

13A   

Range 

Minimum 30 m in door 100m outdoor line of sight 

Operating Temperature  0°C ~ 40°C 
Frequency Range 

868.40MHz & 869.85MHz/EU/CN(PAN11-1B/-2B/-3B/-8B), 
908.40MHz & 916.00MHz/UL 
922~927MHz/TW/JP(PAN11-5B)

 

** Specifications are subject to change and improvement without notice.                           

 

 

 

FCC ID : RHHPAN11

 

 

 

 

 

Warning: 

1.Plug out to disconnect from power supply; Do not plug in line.

 

 

2. Do not exceed the max rating   

Disposal   

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to 
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling.

 

 

Company of License Holder

Philio Technology Corporation 

Address of License Holder

8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New 

Taipei City 24257,Taiwan(R.O.C) 

     

 

   

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules.   

These limits are designed to provide reasonable protection against harmful interference in a 

 

China type PAN11-8B

 

Содержание PAN11-1B

Страница 1: ...lashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be e...

Страница 2: ...the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do no...

Страница 3: ...ommand Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consu...

Страница 4: ...ge V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report...

Страница 5: ...eport its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold...

Страница 6: ...On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update o...

Страница 7: ...sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU CN PAN11 1B 2B 3B 8B 908 40MHz 916 00MHz UL 922 927MHz TW JP PAN11 5B Specifications are subject to change and improvement w...

Страница 8: ...ng antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an...