background image

 

 

TSTFR

X

=

frequency

Setting the supervision test report sending frequency 
assigned to IP addresses: substitute "X" with the ordinal 
number of the IP address. The frequency value should be 
entered in seconds. 

AUTOIP=

dialed number

#

 

Setting the number dialed by the alarm control panel for 
the “

Automatic IP selection

 option. 

SELFID=

SIA user ID

Sets the SIA user ID. 

GSMS=

Y

Sets the

 

„GSM call filtering”

 option. 

Y=0 (call filtering disabled) 
Y=1 (call filtering enabled) 

SPH

X

=

phone number

Setting the phone numbers for backup GSM voice call 
filtering: substitute "X" with the ordinal number of the 
DTMF receiver phone number to be set or modified. 

SFW=

phone number

Sets the phone number where incoming SMS messages 
will be forwarded. 

FWVER?# 

Module firmware version query. 

TROUT?# 

Querying outgoing data traffic counter. The value in the 
response message is specified in Bytes. 

TRIN?# 

Querying incoming data traffic counter. The value in the 
response message is specified in Bytes. 

TRALL?# 

Querying total data traffic counter. The value in the 
response message is specified in Bytes. 

GMIC=

X

Adjusts the microphone volume (outgoing Contact ID 
volume). 

Substitute X with a number between 0…15. 

Default setting: 3. 

GSPK=

X

Adjusts the speaker volume (incoming HSK/ACK volume). 
Substitute X with a number between 0…100. 
Default setting: 50. 

 

Configuring  commands  must  always  end  with  hash  "

#

"  character.  It  is  also  possible  to 

send multiple commands in one SMS, but the message must not exceed 160 characters. 
If the response SMS to be received from the module would exceed 160 characters, only 
the  first  160  characters  are  sent.  In  case  of  making  typing  or  command  mistakes,  the 
following response SMS will be received: "

SYNTAX ERROR!

" and the command(s) will 

not be executed. The module accepts SMS commands sent from the 

Superuser

 phone 

number only. 

Deleting settings: 

To delete a setting, do not enter any value after the equality sign. This can be applied for 
all configuring commands found in the spreadsheet above. Example: 

PH2=#

 

: deletes the second dialed number assigned to the second IP address 

IP3=#

 

: deletes the third IP address 

SPH3=#

 

: deletes the third backup GSM phone number 

SFW=# 

: deletes the SMS forwarding phone number 

Содержание ecoLINE SIA

Страница 1: ...ecoLINE SIA IP Adapter INSTALLATION AND APPLICATION MANUAL for module version v5 02 and higher Rev 1 6 15 09 2015...

Страница 2: ...for backup GSM call 5 3 1 6 Modification of the settings by SMS 6 3 1 7 Incoming SMS message forwarding 6 3 2 Configuring by SMS commands 6 4 Volume adjusting application 9 5 Module status 10 5 1 LED...

Страница 3: ...iguring the communication protocol is not necessary 2 Functions Converting Contact ID format and event reporting in SIA IP format Supports receiver side static IP and domain as well Backup Contact ID...

Страница 4: ...Windows XP SP2 Windows 7 32 64 bit Windows 8 x 32 64 bit Windows 10 32 64 bit Using the programming software the following parameters can be configured 3 1 1 GPRS settings APN name access point name...

Страница 5: ...is option cannot be changed Estimated data traffic indicates the estimated monthly data traffic according to the configured supervision test report sending frequency ATTENTION THE INDICATED ESTIMATED...

Страница 6: ...RUSER The module sets the sender s phone number as Superuser The module accepts this command only if no Superuser has been set yet SU Deletes the current Superuser phone number The module accepts this...

Страница 7: ...raffic counter The value in the response message is specified in Bytes GMIC X Adjusts the microphone volume outgoing Contact ID volume Substitute X with a number between 0 15 Default setting 3 GSPK X...

Страница 8: ...nfigure the first number dialed by the alarm control panel e g 1111 assigned to the first IP address e g 111 112 113 114 with port number e g 9999 send the following SMS message to the module s phone...

Страница 9: ...e connects to the module automatically then Read and Set buttons become available Read the actual settings from the module by clicking on Read from module button Mic volume microphone volume outgoing...

Страница 10: ...hardware Firmware version version of the firmware System timer Date time internal timer of the connected module Uptime elapsed time since the latest module restart GSM status GSM signal current GSM si...

Страница 11: ...ems or and wave interference fading use another directed type of antenna or find a more suitable place for the module 6 2 Putting into operation Disable PIN code request voicemail and missed call noti...

Страница 12: ...Transmission frequency GSM 900 1800 MHz 850 1900 MHz GSM phone type Simcom SIM900 Dimensions 100 x 70 x 19mm Weight 80g packed 100g 7 2 Generated phone line specification Line voltage 48 V Line curren...

Отзывы: