![tell ecoLINE SIA Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/tell/ecoline-sia/ecoline-sia_installation-and-application-manual_1083860008.webp)
8
Settings query:
For settings query insert a question mark after the command. This can be applied for all
configuring commands in the spreadsheet above. Example:
PH2?#
: querying the second dialed number assigned to the second IP address
IP3?#
: querying the third IP address
SPH3?#
: querying the third backup GSM phone number
SFW?#
: querying the SMS forwarding phone number
Examples for SMS command usage:
To configure the first number dialed by the alarm control panel (e.g. 1111) assigned to
the first IP address (e.g. 111.112.113.114) with port number (e.g. 9999), send the
following SMS message
to the module’s phone number:
PH1=1111#IP1=111.112.113.114#PORT1=9999#
To
erase
a
dialed number
configured earlier, leave the "
dialed number
" part blank (e.g.:
to erase the second number dialed by the alarm control panel, send:
PH2=#
command).
For
dialed number query
, leave out the eq
uality “=” sign and use question mark “?”
instead of the
“dialed number”
(e.g.: to request the second number dialed by the alarm
control panel, send:
PH2?#
command).