5
Dialed number:
when the alarm control panel dials the number entered here, the
signals will be forwarded to the IP address assigned to this number. The number set
here must be exactly the same as the one dialed by the alarm control panel,
otherwise the module will not emit the handshake signal.
Remote IP address:
enter the IP address or domain availability of the receiver to
which the signals should be forwarded when the alarm control panel dials the
number assigned to this address.
Connecting to a domain is possible only if the SIM card inserted into the module
uses an APN which includes a DNS server as well. Domains cannot be used when
using a private APN.
Port:
enter the port number of the IP address, through which the receiver receives
the signals.
Test report frequency:
enter the supervision test report sending frequency in
seconds, which is used to monitor the connection between the module and the
receiver found at the given IP address.
Test report sending:
if this option is enabled, the module will always send
supervision signals to the given IP address by the configured frequency. If this
option is disabled, the module sends supervision signals to the given IP address
only when it is absolutely necessary, when the higher priority IP addresses are not
available for some reason. The module always sends supervision signals to highest
priority (first) IP address, this option cannot be changed.
Estimated data traffic:
indicates the estimated monthly data traffic according to the
configured supervision test report sending frequency.
ATTENTION! THE
INDICATED ESTIMATED DATA TRAFFIC IS CONSIDERED ONLY FOR THE
TEST REPORTS, IT IS NOT EQUIVALENT WITH THE
MODULE’S TOTAL
MONTHLY DATA TRAFFIC!
3.1.3 Automatic IP selection
When the alarm control panel dials the number entered here, the events will be sent to
the highest priority available IP address. The priorities correspond to the physical order of
the IP addresses (SIA-IP1 to SIA-IP4).
3.1.4 SIA user ID
Enter here the user account ID programmed in the alarm control panel. In case of using
multiple partitions / user account IDs
, enter the first partition’s user account ID.
The module sends the supervision test reports using this user ID. The length of the SIA
user ID can be minimum 1, maximum 6 characters. Do not fill the user ID with zeros!
3.1.5 Dialed numbers for backup GSM call
If the
“
GSM call filtering
”
option is enabled, and the alarm control panel dials one of the
phone numbers configured in the
“
Dialed numbers for backup GSM call
”
section, the
module will initiate a GSM voice call to the specified phone number and will let the alarm
control panel communicate through this call
.
If this filter is disabled and the alarm control
panel dials any number which is not configured in the module, reporting will be done over
GSM voice call.
Maximum 6 phone numbers of switched-line receivers can be configured which can be
called by the alarm control panel for reporting over backup GSM voice call.