After you finished remote programming the alarm control panel, you can delete the created virtual
serial port by clicking on the “
Delete port
” button.
6 Arming and disarming the alarm control panel through the mobile application
It is possible to arm and disarm a partition in the connected alarm system via the mobile
application, if the given alarm control panel can be armed and disarmed by dry relay contact pulses
through one of its inputs. To use this feature, connect the relay output (
OUT
and
COM
) of the
ecoLINE PRO
to the alarm control panel
’s input used for arming and disarming, set the given
input in the alarm control panel to normally open (
NO
) pulse control, and then configure the control
mode of the device’s output in the
Output
menu. Select the
Monostable
option (you can leave
the pulse duration setting on the factory default value of 1500 milliseconds), and set the number
of the
Controlled partition
.
After doing the wiring and configuring the settings correctly, to arm and disarm the alarm system,
activate the output of the
ecoLINE PRO
in the mobile application using the button provided with
the padlock symbol. Each output activation action will close the
OUT
and
COM
terminals for the
configured period of time (1.5 seconds), and then will revert to default open state automatically.
The contact pulses generated this way will arm and disarm the alarm system through the alarm
control panel’s input appropriate for this. As soon as the alarm system reports the arming or
disarming event, this will trigger the color and status change of the control button in the mobile
application, which is intended to indicate the partition status change.
For this function to work, and in order to receive state messages on arming and disarming in the
mobile application, reporting of arming and disarming events should be enabled in the alarm
control panel, and the number of the controlled partition should be set correctly in the output
settings of the
ecoLINE PRO
device.