1 Module operation 

Application areas: can be used as accessory for alarm control panels or as individual 
GSM signaling device with 2 inputs. 

1.1 Functions 

  GSM voice call to 4 user phone numbers on input activation with recordable 

message or siren tone 

  SMS with adjustable text about each event 

  Report to monitoring station with Contact-ID protocol about each event  

  Remote control of relay output with free call 

1.2 Features 

  4 user phone numbers for GSM voice call and SMS 

  SMS forwarding to the first user phone number 

  1 monitoring station phone number for reporting 

  2 NO/NC inputs 

 1 

relay 

output 

1.3 Events 

 

Alarm events 

The communicator initiates GSM voice call with recordable message or siren tone and 
sends SMS with adjustable text to 4 user phone numbers at the effect of input activation. 
At the same time it sends report to 1 monitoring station phone number with Contact-ID 
protocol. Event restoration is sent only to monitoring station. The module tries to perform 
calls and SMS sending on an event for 10 minutes from occurrence, and it stops the 
alarm of this event when time expires even if it fails to communicate to some of the 
phone numbers during this time. Alarm event occurring occasionally during programming 
interrupts programming, hangs up and starts immediately notification process.  

 

Supply voltage monitoring 

The module sends SMS to the first two user phone numbers and report to the monitoring 
station in at most 24 hour interval, if the supply voltage level falls for at least 1 minute 
below 11,6VDC or 23,2VDC, depending on the power source (applying supply voltage 
above 18VDC already means operation on 24V). Event restoration is sent in SMS to the 
same phone numbers, and to monitoring station via GSM voice call. The module does 
not monitor the supply voltage for the first 60 seconds from power up. Low voltage event 
occurring occasionally during programming is notified right after programming is finished. 
Supply voltage monitoring is enabled by default, can be disabled in the settings menu. 

 

Test report 

The module sends test report (alive signal) in adjustable interval in SMS to the first user 
phone number, as well as with GSM call to monitoring station. Time of day for test report 
sending can be set by pressing the program button shortly three times consequently in 
the desired moment. Then the module sends the test report and the following ones are 
sent in the set interval, in the same time of day. When module reset is performed, the 
test report is sent after 3 minutes from reset, and the following ones are sent likewise in 
the set interval. Test report event occurring occasionally during programming is notified 
right after programming is finished. If value 0 is set for this option, the module does not 
send test report. Test report interval default setting is 7 days. 

Содержание Compact-GSM

Страница 1: ...Compact GSM INSTALLATION AND APPLICATION MANUAL for module version v1 21 and higher Rev 1 5 16 12 2009 ...

Страница 2: ...ustable parameters 6 2 2 Program menu structure 7 2 3 Structure of SMS containing settings 8 2 4 Modification of event SMS texts 8 3 Module overview 9 4 LED signals 9 5 Wiring diagram 10 6 Installation guide 11 6 1 Mounting 11 6 2 Putting into operation 11 7 Technical details 11 7 1 Technical specification 11 7 2 Contents of the package 11 ...

Страница 3: ...ocess Supply voltage monitoring The module sends SMS to the first two user phone numbers and report to the monitoring station in at most 24 hour interval if the supply voltage level falls for at least 1 minute below 11 6VDC or 23 2VDC depending on the power source applying supply voltage above 18VDC already means operation on 24V Event restoration is sent in SMS to the same phone numbers and to mo...

Страница 4: ...The relay output can be activated by initiating a call to the module s phone number from the 4 user phone numbers using identification of caller phone number or from any phone number without identification depending on the setting Relay control mode is monostable activation time is adjustable between 0 9999 seconds Default setting 1s User phone numbers Maximum 4 phone number can be set where the m...

Страница 5: ...BATTERY OK Periodic test report 602 TEST REPORT User account ID The user account ID is a 4 digit identifier which is necessary for reporting to monitoring station and is supplied by the monitoring station The module supports only decimal characters Default setting 0000 Recordable voice messages For each of the two inputs a voice message can be recorded with a maximum length of 6 seconds each If no...

Страница 6: ...n restores all parameters to factory default according to Adjustable parameters table For this keep the button pressed for at least 10 seconds then release see LED signals chapter 2 Programming Programming of the module can be performed through call center For this the program button must be pressed for 3 5 seconds then released Thereafter the module enters the programming mode and accepts call to...

Страница 7: ...g station phone number Key 2 Enter user account number Key 3 Event code settings Key 1 Enter event code for input 1 Key 2 Enter event code for input 2 Key 3 Enter event code for low supply voltage Key 4 Enter event code for periodic test report Key 4 Other parameters and settings Key 1 Enter test report period Key 2 SMS forwarding settings Key 1 Enable SMS forwarding Key 0 Disable SMS forwarding K...

Страница 8: ...EP Y Supply voltage monitoring setting Low voltage report Y enabled N disabled CALLID CHK N Caller identification Y enabled N disabled 2 4 Modification of event SMS texts If it is needed the default texts of event SMS messages can be modified by sending command SMS to the module The command SMS has to be sent when the module is in programming mode therefore it is recommended to write the command S...

Страница 9: ...links with longer intervals Event transmission in progress Green blinks impulsely Red is not lit GSM network is available standby status Green performs a determined number of blinks after pressing the program button GSM signal strength query Orange blinks fast Programming mode Orange is continuously lit Restore settings to factory default reset ...

Страница 10: ...10 5 Wiring diagram For Normally Open setting For Normally Closed setting ...

Страница 11: ...n the SIM card placed into the module Enable caller ID sending service on the SIM card at the GSM service provider If caller identification is used this service must be enabled on the SIM card placed into the module a few types of SIM cards do not have this function enabled by default Check the SIM card to be placed into its case properly Check the antenna to be fixed properly to the Compact GSM m...

Отзывы: