ME310G1 Hardware Design Guide
1VV0301588 Rev. 12
Page 44 of 96
2021-06-14
Fast shut down by hardware
The Fast Power Down can be triggered by configuration of any GPIO. HI level to LOW level
transition of GPIO triggers fast power down procedure.
Example circuit:
Fast shut down by software
The Fast Shut Down can be triggered by AT command.
Note: Consider voltage drop under max current conditions when
defining the voltage detector thereshold in order to avoid unwanted
shutdown.