telindus1031/g703[ ]/channel[ ]/ifOperStatus
This attribute displays the current operational status of the interface. This is an SNMP MIB2 parameter.
Possible values are:
Important remarks
• Whether the Telindus 1031 Router is configured in bridging or routing has no effect on the value of
the attributes
telindus1031/wanInterface/ifOperStatus:Status
and
telindus1031/wanInterface/alarmInfo/link-
Down:Alarms
.
• In case of Frame Relay, if the configuration element
telindus1031/wanInterface/frameRelay/lmi/auto
is set to
noLmi
, then the value of the status element
telindus1031/wanInterface/frameRelay/lmi/status:Status
is always
up
. However, the other conditions as stated in the table above remain.
• In case of PPP, if the configuration element
telindus1031/wanInterface/ppp/linkMonitoring/operation
is set to
disabled
, then it is possible that the
wanInterface/ifOperStatus
value does not go down even if the link qual-
ity is too bad for a proper data link. This because the link monitoring mechanism is the only PPP
mechanism that will start a renegotiation of the LCP layer.
• In case of ATM, if the configuration element
telindus1031/wanInterface/atm/pvcTable/atm/oamF5Loopback
is
set to disabled, then the
ifOperStatus
of the PVC becomes up when the ATM is synchronised globally.
However, this does not guarantee that the PVC is configured (correctly) on the remote side. However,
the other conditions as stated in the table above remain.
Value
Description
up
The WAN interface is up, data transfer is possible.
The following table shows you in which case the value of the
ifOperStatus
attribute
is up:
down
The WAN interface is down, data transfer is not possible.
Protocol
The
ifOperStatus
attribute is
up
(i.e. the alarm
wanInterface/alarmInfo/linkDown = off
) in case …
Frame Relay
• LMI is up.
• the bit pump is synchronised.
PPP
• LCP is open.
• the bit pump is synchronised.
ATM
• the PVC is truly up.
• the bit pump is synchronised.
Содержание 1031
Страница 11: ...Telindus 1031 Router User manual 1 User manual ...
Страница 12: ...Telindus 1031 Router User manual 2 ...
Страница 38: ...Telindus 1031 Router Chapter 2 User manual Installing and connecting the Telindus 1031 Router 28 ...
Страница 80: ...Telindus 1031 Router Chapter 5 User manual Basic configuration 70 ...
Страница 168: ...Telindus 1031 Router Chapter 8 User manual Configuring the bridge 158 ...
Страница 179: ...Telindus 1031 Router Reference manual 169 Reference manual ...
Страница 180: ...Telindus 1031 Router Reference manual 170 ...
Страница 308: ...Telindus 1031 Router Chapter 11 Reference manual Status attributes 298 ...
Страница 336: ...Telindus 1031 Router Chapter 12 Reference manual Performance attributes 326 ...
Страница 348: ...Telindus 1031 Router Chapter 13 Reference manual Alarm attributes 338 ...
Страница 362: ...Telindus 1031 Router Chapter 15 Reference manual Auto installing the Telindus 1031 Router 352 ...
Страница 370: ...Telindus 1031 Router Chapter 16 Reference manual Downloading software 360 ...
Страница 380: ...Telindus 1031 Router Chapter 17 Reference manual Technical specifications 370 ...
Страница 381: ...Telindus 1031 Router Annex 371 Annex ...
Страница 382: ...Telindus 1031 Router Annex 372 ...
Страница 384: ...Telindus 1031 Router Annex A Annex common TCP and UDP numbers 374 ...
Страница 386: ...Telindus 1031 Router Annex B Annex product information 376 ...
Страница 394: ...Telindus 1031 Router Index Annex 384 ...