![Telindus 1031 Скачать руководство пользователя страница 206](http://html.mh-extra.com/html/telindus/1031/1031_user-and-reference-manual_1083538206.webp)
Telindus 1031 Router
Chapter 10
Reference manual
196
multiProtocolMech
Use this element to define how the protocol has to be
mapped onto ATM Adaptation Layer 5 (AAL5).
The
multiProtocolMech
element has the following values:
The following table gives an overview of which multi-protocol mechanism can be
used for which higher layer protocol encapsulation. It also shows whether this can
be combined with NAT/PAT.
peakCellRate
Use this element to set the maximum bandwidth of the
PVC.
The
peakCellRate
element has the following values:
auto
and
64kbps
up to
2304kbps
in
steps of
64kbps
. In auto mode, the PVC will try to get the maximum bandwidth, i.e.
the speed of the physical connection towards the ATM network.Refer to
for more information on the peak cell rate.
inArpTimeOut
Use this element to set the time between the trans-
mission of two consecutive Reverse ARP frames.
oamF5Loopback
Use this element to configure the transmission of
OAM F5 loop-back cells.
Refer to
telindus1031/g703[ ]/channel[ ]/atm/pvcTable/atm/oamF5Loopback
for a
detailed description of the
oamF5Loopback
structure.
Element
Description
Default:llcEncapsulation
Range: enumerated, see below
Value
Description
llcEncapsulation
Logical Link Control (LLC) encapsulation multiplexes
multiple protocols over a single virtual circuit. The proto-
col of a carried protocol data unit (PDU) is identified by
prefixing the PDU with an LLC header.
vcMultiplexing
Virtual Circuit (VC) based multiplexing uses one Virtual
Channel (VCI/VPI pair) for each protocol. This uses
more VCs than LLC encapsulation, but reduces over-
head, because a header is not necessary.
Device as router or
bridge?
higherLayerProtocol
multiProtocolMech
NAT/PAT
support
router
rfc2684
llcEncapsulation
yes
ppp
llcEncapsu
vcMultiplexing
yes
pppOverEthernet
llcEncapsulation
yes
bridge
rfc2684
llcEncapsulation
no
ppp
llcEncapsu
vcMultiplexing
no
pppOverEthernet
llcEncapsulation
no
Default:auto
Range: enumerated, see below
Default:00000d 00h 00m 30s
Range: 00000d 00h 00m 01s -
00000d 01h 00m 00s
Default:-
Range: structure, see below
Содержание 1031
Страница 11: ...Telindus 1031 Router User manual 1 User manual ...
Страница 12: ...Telindus 1031 Router User manual 2 ...
Страница 38: ...Telindus 1031 Router Chapter 2 User manual Installing and connecting the Telindus 1031 Router 28 ...
Страница 80: ...Telindus 1031 Router Chapter 5 User manual Basic configuration 70 ...
Страница 168: ...Telindus 1031 Router Chapter 8 User manual Configuring the bridge 158 ...
Страница 179: ...Telindus 1031 Router Reference manual 169 Reference manual ...
Страница 180: ...Telindus 1031 Router Reference manual 170 ...
Страница 308: ...Telindus 1031 Router Chapter 11 Reference manual Status attributes 298 ...
Страница 336: ...Telindus 1031 Router Chapter 12 Reference manual Performance attributes 326 ...
Страница 348: ...Telindus 1031 Router Chapter 13 Reference manual Alarm attributes 338 ...
Страница 362: ...Telindus 1031 Router Chapter 15 Reference manual Auto installing the Telindus 1031 Router 352 ...
Страница 370: ...Telindus 1031 Router Chapter 16 Reference manual Downloading software 360 ...
Страница 380: ...Telindus 1031 Router Chapter 17 Reference manual Technical specifications 370 ...
Страница 381: ...Telindus 1031 Router Annex 371 Annex ...
Страница 382: ...Telindus 1031 Router Annex 372 ...
Страница 384: ...Telindus 1031 Router Annex A Annex common TCP and UDP numbers 374 ...
Страница 386: ...Telindus 1031 Router Annex B Annex product information 376 ...
Страница 394: ...Telindus 1031 Router Index Annex 384 ...