2.3.3.
To Emergency Signal Switch
To use the emergency function, fire alarm linked
trigger interface (normally open) must be
connected to the emergency switch connector.
When the switch is closed the audio signal on the
Aux-Right input is distributed to all output channels
and overriding all other audio inputs.
”ALARM” will be displayed at this moment.
Figure 2.6: Transmitter connected to emergency signal
switch
2.3.4.
To Another Transmitter
Bypass ( bypass) mode
The transmitter can be operated in bypass mode to
loop-through the IR radiator signals from another
transmitter. Multi room application can be achieved
by setting the transmitter in the main room to
“Master” mode and the transmitters in other rooms
to “Bypass” mode. One of the 4 radiator outputs of
the master transmitter is connected with an RG-58
cable to the radiator signal loop-through input of
the bypass transmitter (see Figure 2.7). The 2
transmitters should be set to “Master” and
“Bypass” respectively (see section 2.5.6).
Figure 2.7: Transmitter connected to another transmitter
in bypass mode