1. General Description
UWE432 is a universal device for expanding existing wired alarm security systems. UWE432 communi-
cates by means of two-way radio connection with wireless devices AVA series. The UWE432 supports
up to 32 AVA series wireless devices.
There are three possible types for grouping of the used wireless devices: by functionality, by premises
or combination of both.
2. Functional Working Diagram
3. UWE432 Control Module
3.1 LED Indication
•
LED
- Color
indication for the UWE432 status:
Green
- Power supply presence;
Red
- LEARN Mode;
Orange
- Viewing TROUBLES Mode.
•
Z1 - Z4 -
Zone 1 - Zone 4 status indication;
•
Sounders -
Status indication of the sirens.
3.2 Terminal Rows
•
АC/DC
- Power supply - 10
÷
30 Vdc;
•
In1
- Input for resetting wireless fire detectors (time for
reset ≥ 2 seconds), the active state towards GND is 0V;
•
In2
- Input for wireless siren control (time for reset ≥ 2
seconds), the active state towards GND is 0V;
•
In3
- Used only in case AVA RC 102TE remote control is
enrolled to UWE432 receiver module; this is an input for
monitoring of the control panel status. The functionality of
In3 depends on the type of the PGM at the control panel -
see Table 1.
•
Z1, Z2, Z3, Z4
- Outputs with CA62 interface / universal
interface for direct zone connecting;
•
GND
- Common ground.
•
OUT1
- Relay output (NO) for
Low Battery
and
Lost Device
state of wireless devices;
•
OUT2
- Relay output (NC) for
TAMPER
state of wireless devices and the UWE432 box; Connect to a
TAMPER type zone of the control panel.
B
- Mounting holes for fixing to the bottom of small universal plastic box.
C
- Mounting holes for fixing to the bottom of big universal plastic box.
Control
Panel
Compatible wireless devices AVA series:
- AVA P-REX and AVA TITAN (PIR detectors);
- AVA MC (magnetic contact);
- AVA FD (fire detector);
- AVA RC 102TE (remote control unit);
- SR200R* (outdoor siren).
* Note: Up to 2 outdoor sirens
SR200R can be enrolled to the
UWE432 universal receiver!
!