PRISM MPI2-10 and MPX2-10 Field Upgrade Kit Instructions 

 

To safely perform service on this product, see the Service safety summary that follows the 

General safety summary.  

 

General Safety Summary  

Use the product only as specified. Review the following safety precautions to avoid injury 

and prevent damage to this product or any products connected to it. Carefully read all 

instructions. Retain these instructions for future reference.  

 

Comply with local and national safety codes.  

For correct and safe operation of the product, it is essential that you follow generally 

accepted safety procedures in addition to the safety precautions specified in this manual.  

 

The product is designed to be used by trained personnel only.  

Only qualified personnel who are aware of the hazards involved should remove the cover 

for repair, maintenance, or adjustment.  

 

Before use, always check the product with a known source to be sure it is operating 

correctly.  

 

While using this product, you may need to access other parts of a larger system. Read the 

safety sections of the other component manuals for warnings and cautions related to 

operating the system.  

 

When incorporating this equipment into a system, the safety of that system is the 

responsibility of the assembler of the system.  

 

To Avoid Fire or Personal Injury  

Use proper power cord:

 Use only the power cord specified for this product and certified for 

the country of use. Do not use the provided power cord for other products.  

 

Ground the product:

 This product is grounded through the grounding conductor of the 

power cord. To avoid electric shock, the grounding conductor must be connected to earth 

ground. Before making connections to the input or output terminals of the product, ensure 

that the product is properly grounded. Do not disable the power cord grounding connection.  

 

Power disconnect:

 The power cord disconnects the product from the power source. See 

instructions for the location. Do not position the equipment so that it is difficult to operate 

the power cord; it must remain accessible to the user at all times to allow for quick 

disconnection if needed.  

 

Observe all terminal ratings:

 To avoid fire or shock hazard, observe all rating and 

markings on the product. Consult the product manual for further ratings information before 

making connections to the product. Do not apply a potential to any terminal, including the 

common terminal, that exceeds the maximum rating of that terminal. 

 

Do not operate without covers:

 Do not operate this product with covers or panels removed, 

or with the case open. Hazardous voltage exposure is possible.  

 

Avoid exposed circuitry:

 Do not touch exposed connections and components when 

powered.  

 

Do not operate with suspected failures:

 If you suspect that there is damage to this product, 

have it inspected by qualified service personnel.  

 

Содержание MPI2-10-UP PHY

Страница 1: ...PRISM MPI2 10 and MPX2 10 Media Analysis Platform Field Upgrade Instructions www telestream net 075 1136 00A...

Страница 2: ...by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TELESTREAM is a r...

Страница 3: ...on 1 Supported upgrades 1 Kit parts list 1 MPI2 10 hardware upgrades 2 Recommended tool list 2 Upgrade the PRISM MPI2 10 Eye mezzanine board 3 MPX2 10 hardware upgrades 9 Recommended tool list 9 Upgra...

Страница 4: ...device must accept any interference received including interference that may cause undesired operation Safety UL 61010 1 2012 R4 16 Safety Requirements for Electrical Equipment for Measurement Contro...

Страница 5: ...NCE GERMANY GREECE HUNGARY IRELAND ITALY LATVIA LITHUANIA LUXEMBOURG MALTA NETHERLANDS POLAND PORTUGAL ROMANIA SLOVAKIA SLOVENIA SPAIN SWEDEN UNITED KINGDOM ICELAND LICHTENSTEIN NORWAY SWITZERLAND Dec...

Страница 6: ...at will ensure that most of the materials are reused or recycled appropriately This symbol on the product or its packaging indicates that this product complies with the applicable European Union requi...

Страница 7: ...s an industrial monitoring and control instrument and is not required to comply with the substance restrictions of the RoHS 3 Directives 2011 65 EU and EU 2015 863 until July 22 2021 This product does...

Страница 8: ...roper power cord Use only the power cord specified for this product and certified for the country of use Do not use the provided power cord for other products Ground the product This product is ground...

Страница 9: ...Provide a safe working environment Always place the product in a location convenient for viewing the display and indicators Be sure your work area meets applicable ergonomic standards Consult with an...

Страница 10: ...bol s may appear on the product General Safety Product Specific Statements Use the product only as specified Review the following safety precautions to avoid injury and prevent damage to this product...

Страница 11: ...er to have the system firmware restored DO NOT remove power from the instrument during the upgradeprocess CAUTION Bending the Eye mezzanine board can damage the board or instrument Avoid fully inserti...

Страница 12: ......

Страница 13: ...support MPX2 10 UP PHY Add SDI Physical Layer Measurement Package to the MPX2 10 product includes automated measurement of 12G 3G HD SD SDI Eye pattern parameters and jitter parameters and jitter wave...

Страница 14: ...tible to static discharge damage To prevent static discharge damage service the product only in a static free environment Observe standard handling precautions for static sensitive devices while insta...

Страница 15: ...nstrument and install the Eye mezzanine board 1 Set the instrument so the bottom is down on a static free work surface 2 Remove the top cover as follows a Use a TORX driver with a T 10 TORX tip to rem...

Страница 16: ...9 16 inch socket nut driver to remove the two BNC nuts and lock washers SDI IN 1 and 2 Figure 2 Remove the BNC hardware 4 Using a TORX driver with a T 10 TORX tip to remove the screw securing the BNC...

Страница 17: ...ntly lift the back of the BNC mezzanine board from its connector and remove it from the Mixed Media board Figure 4 Remove mezzanine board from Mixed Media board 6 Locate the new Eye mezzanine board fr...

Страница 18: ...ctor until the front connector is properly aligned this prevents the bending of the board 8 Begin by engaging the connector near the BNCs Do not fullyinsert 9 Line up the connectors furthest away from...

Страница 19: ...zzanine board Tighten these screws to 0 6 N m 5 31 in lb Figure 7 Secure the Eye mezzanine board 12 Replace the two BNC nuts and lock washers Tighten the BNC nuts to 1 0 N m 8 85 in lb 13 Place the to...

Страница 20: ...contain the regulatory marks NOTE The MPI2 10 UP serial number label is included in the upgrade kit The label lets Telestream service know that the instrument contains the upgrade kit Figure 8 Instal...

Страница 21: ...nt are susceptible to static discharge damage To prevent static discharge damage service the product only in a static free environment Observe standard handling precautions for static sensitive device...

Страница 22: ...board from the instrument and install the Eye mezzanine board 1 Set the instrument so that the bottom is down on a static free surface 2 Remove the top cover as follows a Use a TORX driver with a T 1...

Страница 23: ...BNC nut driver to remove all five BNC nuts and lock washers Figure 10 Remove the rear panel plate hardware 4 Use a TORX driver with a T 10 TORX tip to remove the four screwssecuring the rear panel pla...

Страница 24: ...panel NOTE The GPIO board will keep the rear plate connected to the instrument Figure 12 Remove the rear panel plate 6 Use a TORX driver with a T 10 TORX tip to remove the two screws oneither end of t...

Страница 25: ...rd module Figure 14 Loosen the lock nuts securing the Mixed Media board module to the instrument 9 Slide the Mixed Media board and carrier frame away from the PCIe and power connector on the Slot Host...

Страница 26: ...move the Mixed Media board from the grinches 12 Turn the board over and disconnect the GPIO ribbon cable CAUTION Make sure the back panel is pulled out enough to clear the BNC connectors on the Mixed...

Страница 27: ...rd 15 Refer to Figure 19 and install the screw from the kit part number 211 1117 XX and the spacer post part number 129 1889 XX into the hole closest to second connector using the following method a I...

Страница 28: ...ye mezzanine board with both of the connectors and press down until it is fully engaged as show in Figure 20 CAUTION Bending the Eye mezzanine board can damage the board or instrument Avoid fully inse...

Страница 29: ...instrument Tighten the four Mixed Media board bracket screws to 0 6 N m 5 31 in lb 20 Secure the back panel to the instrument Tighten two side screws to 0 9 N m 7 97 in lb 21 Tighten the two lock nut...

Страница 30: ...Telestream service know that the instrument contains the upgrade kit Figure 22 Installing the MPX2 10 UP serial number label CAUTION The MPX2 10 UP label is not inset and is at risk of damage To avoi...

Страница 31: ...mware at the Telestream website a On a PC go to the Telestream website software page www telestream net video resources htm Software b Click on the product and model title that best matches your instr...

Страница 32: ...lect the Settings icon to open the Settings menu 4 Select Utilities to open the Utilities submenu 5 Select Firmware Upgrade After the USB device has been scanned the display lists all of the files on...

Страница 33: ...the USB device from the PRISM monitor Verify the firmware upgrade 1 Select the Settings icon to open the Settingsmenu 2 Select Utilities to open the Utilities submenu 3 Select Version to open the Vers...

Страница 34: ...ess select Settings then Network and finally select the STATUS tab 3 Copy the IP address of the instrument under the CONTROL IP PORT heading 4 Open a web browser and enter in the address bar the instr...

Страница 35: ...o the instrument 2 MPX only Connect the external display 3 Connect the TG8000 SDI7 module output to the SDI 1 IN input on the PRISM monitor 4 Set the SDI7 module to HD 1080 59 94i format using the fol...

Страница 36: ...de 5 Select the 100 Color Bars signal using the following steps a On the TG8000 push the front panel BARS test signal button b Use the left or right arrow button or push the BARS test signal button re...

Страница 37: ...gure 26 Settings inputs submenu d Select one of the four physical SDI inputs to monitor The TG8000 SDI7 module output is connected to the SDI 1 input Figure 27 SDI signal configuration e Select Save a...

Страница 38: ...anner Touch the Tool icon and select Align from the Jitter HP Filter drop down list 10 Check for a stable eye diagram Eye Amplitude and the actual wave shape depend on the generator signal Eye Amplitu...

Отзывы: