LSA switching logic

Link fails

LSA delay time

Link gets up

Link doesn't

get up

Initial

state

Normal state

(Switch position: Com - port A)

User definable time

(Waiting time in seconds before 
the switch operates after first 
detected Link Loss Alarm)

LSA control activated

(Switch position: Com - port B)

LSA control is activated

(Switch position: Com - port B)

Link gets up

LSA control is kept activated

(Switch position: Com - port B)

LSA control is kept de activated

(Switch position: Com - port A)

LSA hold time

User definable time

(Waiting time in seconds to 
ensure that optical connection 
has been established successfully)

User definable time

(Waiting time in seconds to 
ensure that optical connection 
has been established successfully)

Link doesn't

get up

LSA control is de-activated

(Switch position: Com - port A)

Link gets up

LSA hold time

Link doesn't

get up

To return the switch back to the initial state, use CLI with a command 

lsareset

 to reset the LSA.

4

 

Optical switch

 user manual rev001

Содержание CFO series

Страница 1: ...Video Networks Optical switch 1 x 2 switch for singlemode bre 1290 1330 and 1470 1610 nm wavelenghts User Manual For CFO series CEV x61 x71 Optical switch user manual 59300281 rev001...

Страница 2: ...1 Frame installation 1 Stand alone installation 1 Fibre connection 1 Operation 2 Link Source Alarm LSA 2 LSA commands 2 Switch port positions and indicator leds 2 Settings 3 Wiring example 3 DIP swit...

Страница 3: ...nd alone installation The unit can be installed for stand alone use by using a CMA series module adapter The unit is to be pushed along the guide rails into the CMA module adapter and secured with the...

Страница 4: ...l wait for the optic link to get up before operating the switch for the first time Displays or set the link source alarm hold time in seconds Holdtime defines the waiting time to ensure the recovery o...

Страница 5: ...ches see settings below The default factory setting is LSA controlled 1 ON 2 3 4 5 6 DIP swithes are located on the bottom of unit Note When the optical switch is configured to LSA mode there is an al...

Страница 6: ...ed Switch position Com port B LSA control is kept de activated Switch position Com port A LSA hold time User definable time Waiting time in seconds to ensure that optical connection has been establish...

Страница 7: ...unless otherwise stated Optical Wavelenght range 1310 50 and 1460 1620 nm Insertion loss 1 0 dB max Return loss 60 dB Switching type 1x2 non latching Switching time 8 ms Cross talk 60 dB min Switching...

Страница 8: ...of the European Parliament and of the Council on waste electrical and electronic equipment WEEE obliges that producers appropriately mark electrical and electronic equipment with the symbol indicatin...

Отзывы: