General

Optical switch is compatible with CEV / CFOx61/x71 series video 
modems and is used to achieve the 

fi

 bre path redundancy. The optical 

bandpass covers CWDM wavelenghts 1460...1620 nm and standard 1310 
nm window. Fully bi-directional optical operation is allowed. When optical 
switch is used in conjunction with a CEV / CFOx61/x71 video modems, 
the optical switching can be automatic when it is controlled by the Link 
Loss Alarm (LSA) available from these video modems. Alternatively the 
optical switch can be con

fi

 gured to operate in case of system power loss 

or to have remotely controlled switching by means of an external I/O 
control. The switching component itself is a durable 1 x 2 type non-
latching switch with a low insertion loss. The unit is 5HP wide.

Frame installation

The unit is to be pushed along the guide rails into the installation frame 
(e.g. CSR216 or 316 series) and secured with the two locking screws. The 
unit can be freely positioned in any slot in the frame. The empty positions 
in the frame should be blanked off with cover plates.The supply voltage is 
to be provided by a 

CPS384 

or

 CPS390

 power supply unit.

Stand-alone installation

The unit can be installed for stand-alone use by using a CMA series 
module adapter. The unit is to be pushed along the guide rails into the 
CMA module adapter and secured with the two locking screws. The 
stand-alone unit should be mounted to a vertical surface. The 12V DC 
supply voltage is supplied by the means of a separate mains adapter 
with a regulated output, (e.g. CPS231).

Fibre connection

When installing the 

fi

 bre optic cable, do not exceed the minimum 

bending radius when connecting cable to the system.
For correct optical operation ensure that: 
>  Protect opened connectors always with dustcaps
>  Only 8° angle polished SC/APC connectors are allowed
>  Clean all connectors before mating by using metyl or 
 

isopropyl alcohol and dry connectors by compressed air

Optical switch for CEV and CFOx61/x71 series
video modems.

Optical switch introduction

DATA 1

EXTERNAL

CONTROL

OPTICAL 

SWITCH

SMF

LSA

2

1

3

4

8

5

6

7

Optical switch, 

front view. 

1. Locking screw (2 pcs)
2. LSA connector
3. Loopthru connector
4. External control connector
5. Port A
6. Port B
7. Common port
8. Handle (with unit information)

LSA and DATA1 port connectors are 
of type RJ-45 female.
All optical port connectors are of type 
SC/APC female (8°).

See further information on 
dedicated sections.

SC/APC 8° optical connection.

Optical switch

 user manual rev001 

1

Содержание CFO series

Страница 1: ...Video Networks Optical switch 1 x 2 switch for singlemode bre 1290 1330 and 1470 1610 nm wavelenghts User Manual For CFO series CEV x61 x71 Optical switch user manual 59300281 rev001...

Страница 2: ...1 Frame installation 1 Stand alone installation 1 Fibre connection 1 Operation 2 Link Source Alarm LSA 2 LSA commands 2 Switch port positions and indicator leds 2 Settings 3 Wiring example 3 DIP swit...

Страница 3: ...nd alone installation The unit can be installed for stand alone use by using a CMA series module adapter The unit is to be pushed along the guide rails into the CMA module adapter and secured with the...

Страница 4: ...l wait for the optic link to get up before operating the switch for the first time Displays or set the link source alarm hold time in seconds Holdtime defines the waiting time to ensure the recovery o...

Страница 5: ...ches see settings below The default factory setting is LSA controlled 1 ON 2 3 4 5 6 DIP swithes are located on the bottom of unit Note When the optical switch is configured to LSA mode there is an al...

Страница 6: ...ed Switch position Com port B LSA control is kept de activated Switch position Com port A LSA hold time User definable time Waiting time in seconds to ensure that optical connection has been establish...

Страница 7: ...unless otherwise stated Optical Wavelenght range 1310 50 and 1460 1620 nm Insertion loss 1 0 dB max Return loss 60 dB Switching type 1x2 non latching Switching time 8 ms Cross talk 60 dB min Switching...

Страница 8: ...of the European Parliament and of the Council on waste electrical and electronic equipment WEEE obliges that producers appropriately mark electrical and electronic equipment with the symbol indicatin...

Отзывы: