Telereef Controller - User Manual V.140313
!
!
!
• pH Sensor settings
!
A.
Raise pH Upper
- The upper pH value of the raise pH
equipment. pH level raise above this value will switch off related
relay/socket.
B.
Raise pH Lower
- The lower pH value of the raise pH
equipment. pH level raise above this value will switch off related
relay/socket.
C.
Raise pH Socket
- Relay/Socket of raise pH equipment bound
to this sensor.
D.
Lower pH Upper
- The upper pH value of the lower pH
equipment. pH level raise above this value will switch on related
relay/socket.
E.
Lower pH Lower
- The lower pH value of the lower pH
equipment. pH level below this value will switch off related
relay/socket.
F.
Lower pH Socket
- Relay/Socket of lower pH equipment bound to this sensor.
G.
Alert Upper
- pH Value above this value will active beep alert or push notification.
H.
Alert Lower
- pH Value below this value will active beep alert or push notification.
I.
Beep Alert
- Enable / Disable beep alert.
J.
Push Notification
- Enable / Disable push notification to Smart Phone.
!
!
• Wireless Dosing Pump Pair Screen
!
!
A.
PA
- The RF Power Amp setting of the WDP. 1=Lowest,
4=Maximum. Default is 3.
B.
Device ID/Version
- The Device ID and the firmware version of
the paired WDP.
C.
Pair/Unpair Button
- Button used to pair or unpaid a WDP.
D. Passcode - The four characters passcode. WDP should
matched the passcode in order to receive a command from
Telereef Controller.
E. Address - The wireless RF starting address which will be used
on WDP. Range from 1 to 200, each WDP unit occupied two
addresses.
F. Channel - The wireless RF starting channel which will be used
on WDP. Range from 1 to 99, each WDP unit occupied one
channel.
!
!
• Wireless Dosing Pump Setting Screen
!
!
A.
Name
- Name of the additive connected to the dosing pump. If the name is blank or
first character of the name is a space, this pump will not be show on Home page.
!
B.
Speed
- Speed of the dosing pump, value from 1 to 255, default speed is 120.
!
C.
ml/m
- The amount of additive output after one minute running time of the dosing
pump. Please update this value after calibrated the dosing pump.
!
27