Telereef Controller - User Manual V.140313
!
channel. If two values are different, which is indicate the channel output is changing
or slow dimming schedule is running.
S.
Auto (Manua
l) - Indicate the channel is in Auto mode or Manual mode.
T.
@x.xx/s
- If the output of channel is changing, this value show the speed of
changing. The speed is calculated according how long does it take to reached to
target output value on Timer Schedule setting. If the output is changed by + / -
button, the dimming speed will be faster at 5% per second.
U.
On Button
- Manually turn on relay socket. The socket will switch to Manual Mode
and ignore timer schedule settings.
V.
Auto Button (Socket Status)
- Switch back to Auto Mode and apply socket status
according current timer schedule setting.
W.
Off Button
- Manually turn off relay socket. The socket will switch to Manual Mode
and ignore timer schedule settings.
X.
Today accumulated
- Accumulated time use on this socket today.
Y.
Reference unit
- Calculation according to the time use and the rate setting at
Socket Name Setting page. For power consumption, operating cost or usage
estimation.
!
a.
Pump #
- Pump number of Telereef Wireless Dosing Pump
and the chemical name which assign to this pump.
b.
1ml Button
- Instant add 1ml of chemical to the aquarium.
c.
5ml Button
- Instant add 5ml of chemical to the aquarium.
d.
10ml Button
- Instant add 10ml of chemical to the aquarium.
e.
Today accumulated
- Amount of chemical added today.
f.
Stock available
- Amount of the chemical remains in the
container estimated can last for how many days.
g.
Last run / Next run
- If there is a timer schedule for this
chemical, it shows what time was the last dosage and what
time will be next dosage.
h.
Stop all running pump now
- Push this button to emergency
stop all running dosing pumps instantly.
!
!
• Setup page
!
!
A.
<< Back Button
- Back to previous page.
B.
Timer Title
- Timer type and related socket or chemical. Push
on this Timer Title you can modify the timer details in Timer
Setting page.
C.
Time
- The time period of the Timer Schedule. Depends on
timer type, it may be a time range, 24 hours (whole day
schedule) or exact activation time.
D.
Day
- Day of week which the timer will enabled.
E.
Target
- The socket or wireless dosing pump which the timer
will activate.
F.
DEL
- Delete the timer.
G.
Select timer
to add pull down menu.
H.
Timer type selection
- After selected a timer type, Timer
Setting page will show up.
I.
Edit Button
(Temperature Settings) - Push this button to setup of modify
Temperature Settings.
21