![Telereef TR1D Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/telereef/tr1d/tr1d_user-manual_1082141011.webp)
Telereef Controller - User Manual V.140313
!
scroll down to pH Sensor Settings, push Edit button and input the following settings
We don’t recommend to control aquarium pH by using this function, using pH controller
to add additives to aquarium is high risk since you never know how much amount of
additives will be added to the aquarium. According to the pH value and create a dosing
pump timer schedule for additive is recommended.
!
• Timers
!
There are six different kinds of timer can be set up in Telereef Controller
!
a.
Regular Timer :
Turn on and turn off specific socket in specific time range, weekly
schedule can also be applied.
b.
Dimming Timer:
Change dimming channels output percentage at specific time. If
“Stop” field also be defined, a slow dimming effect will be applied. Weekly schedule
can also be applied.
For example, if initial output is 0% and the following is defined
means both dimming channels will started to slow increasing from 0% at 8am and
reached to White Channel 80%, Blue Channel 100% at 9am
Another example, if initial output is 100%
means both dimming channels started to slow decreasing from 100% at 6pm and
reached to White Channel 0% and Blue Channel 10% at 8pm, after 8pm only 10%
Blue light is remained, White light is turned off.
!
c.
Interval Timer :
Within a time range, turn on specific socket for specific duration
and turn off specific interval time period. Weekly schedule can also be applied. This
kind of timer is useful for wave making pump or traditional dosing pump.
Lower pH Upper
6.7
Lower pH Lower
6.5
Lower pH Socket
S4
Start
08:00:00
Stop
09:00:00
White
80
Blue
100
Start
18:00:00
Stop
20:00:00
White
0
Blue
10
11