5
OPERATION
Introduction
This section describes the normal operating procedures for the Telemark TT
Power Supplies.
Preliminary Precautions
Before turning on the system for the first time, it is essential that the following
conditions are observed:
1
The ground system is correctly installed as described in detail
in Chapter 3 (Installation), System Grounding Practice.
2
The external interlocks are correctly installed as described in
detail in Chapter 4, Interlock Connections under Control
Modules.
3
The vacuum tank is operational.
4
The filament assembly is assembled to specifications and not
shorted to ground, and the E-beam source has material in its
crucible.
Startup
1
Turn ON the primary source of VAC power to the system. Make
sure that the main cabinet circuit breakers are on.
2
Turn on controller KEYLOCK.
3
Push Main Power on.