MDR Manual
33
E) Priority Record:
Press ENTER to enable or disable Priority Record.
z
Priority Recording records one frame per every second when no external sensor is
sensed by the unit.
z
When a sensor triggers through a sensor input, the unit automatically starts to
record up to the user selected frames/second on all cameras.
z
User can select between the timings before and after the event for high frame rate
recording.
z
Use the Numeric key pad or ARROW down to the second settings to define the
time duration of full-rate recording after and before the trigger is over.
Scroll to
APPLY
and press
ENTER
to save the new settings.