
Teledyne
LeCroy
Batch
Scenario
Overview
230 SierraNet
M408
Protocol
Analyzer
User
Manual
To
remove
a
global
variable,
simply
select
it
on
the
table
and
select
the
Delete
button.
The
variable
is
removed
from
the
right
pane
of
the
dialog.
The
Up
and
Down
arrows
(Figure 5.15)
let
you
rearrange
the
order
of
variable
values
that
you
wish
to
change,
before
Net
Protocol
Suite
runs
a
scenario.
For
most
fields,
the
order
does
not
matter,
but
for
the
fields
that
do
change
the
format
of
events,
this
order
becomes
important.
For
example,
suppose
you
want
to
change
the
value
of
the
field
Opcode
in
a
SCSI
command,
and
then
change
one
of
the
other
fields
in
that
SCSI
command.
You
will
have
to
move
the
Opcode
field
to
the
top
of
the
list,
because
when
you
set
Opcode
fields,
the
event
fields
will
be
changed
automatically.
Then
you
can
change
the
value
of
another
field.
On
the
other
hand,
if
you
want
to
set
the
value
of
a
field
such
as
Originator
S_ID
,
changing
its
value
has
no
effect
on
the
format
of
other
fields
in
an
event,
so
you
don’t
need
to
specify
the
order
in
which
these
fields
are
accessed.
Figure 5.15: Location of Delete button and Up and Down arrows.
Note:
Replacing
any
value
in
a
frame
pattern
or
event
may
cause
other
fields
values
to
reset.
To
avoid
this,
make
sure
you
select
the
correct
order
of
global
variables.
For
example,
assume
there
is
a
batch
scenario
with
one
“Start
Jammer”
command
and
global
variables
as
shown
in
Figure 5.16
and
Figure 5.17.
Figure 5.16: Example of a Batch Scenario.
Содержание SierraNet M408
Страница 1: ...SierraNet M408 User Manual Software Version 1 70 Generated December 15 2014 09 58 ...
Страница 8: ...Teledyne LeCroy Contents viii SierraNet M408 User Manual ...
Страница 12: ...Teledyne LeCroy Analyzer Overview 4 SierraNet M408 User Manual Figure 1 4 LEDs on the Front Panel ...
Страница 40: ...Teledyne LeCroy CrossSync Control Panel 32 SierraNet M408 User Manual ...
Страница 53: ...SierraNet M408 User Manual 45 Application Menu Options Teledyne LeCroy Figure 2 14 Trace Information Dialog 1 ...
Страница 115: ...SierraNet M408 User Manual 107 Advanced Mode User Defined Teledyne LeCroy Figure 2 83 Setting Triggers ...
Страница 117: ...SierraNet M408 User Manual 109 Advanced Mode User Defined Teledyne LeCroy Figure 2 85 Capture Everything ...
Страница 120: ...Teledyne LeCroy Advanced Mode User Defined 112 SierraNet M408 User Manual ...
Страница 159: ...SierraNet M408 User Manual 151 Preferences Teledyne LeCroy Figure 3 48 Software Settings General Options ...
Страница 164: ...Teledyne LeCroy Preferences 156 SierraNet M408 User Manual Figure 3 53 Display Settings General Dialog ...
Страница 213: ...SierraNet M408 Protocol Analyzer User Manual 205 InFusion Scenarios TeledyneLeCroy Figure 4 24 Marker Trigger Menu ...
Страница 224: ...Teledyne LeCroy Running Scenarios 216 SierraNet M408 Protocol Analyzer User Manual ...
Страница 242: ...Teledyne LeCroy 234 SierraNet M408 User Manual ...
Страница 244: ...Teledyne LeCroy 236 SierraNet M408User Manual ...