![Teledyne PIXIS-XF Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/teledyne/pixis-xf/pixis-xf_system-manual_1080552011.webp)
Chapter 1
Introduction
11
1.9
Cleaning
WARNING!
Turn off all power to the equipment and secure all covers
before cleaning the units. Otherwise, damage to the
equipment or personal injury could occur.
1.9.1
Camera
Although there is no periodic maintenance that must be performed on the camera, you
may clean the camera from time to time by wiping it down with a clean damp cloth.
This operation should only be done on the external surfaces and with all covers
secured. In dampening the cloth, use clean water only. No soap, solvents or abrasives
should be used. Not only are they not required, but they could damage the finish of the
surfaces on which they are used.
1.9.2
Beryllium Window
Cleaning may be necessary to remove oil or other contaminants from the surface of the
Beryllium window. Because of the potential toxicity, protective gloves should be worn
when cleaning the window. To clean the window, wipe it down with isopropanol and a
lint free cloth. DO NOT use water. Beryllium is highly susceptible to localized pitting
when in contact with the chloride and sulfate ions contained in ordinary water.
NOTE:
There are no user-serviceable components inside the
fiberoptic taper camera. Refer servicing to qualified
personnel and contact the factory Customer Support for
guidance. Refer to
complete information.
Please save the original packing material so you can safely
ship the system to another location or return it for repairs.
1.10 Conventions Used In this Document
WinX/32 is a generic term for WinSpec/32, WinView/32, and WinXTest/32 application
software. Often WinX/32 and LightField use different terms for the same functions or
parameters. When a topic pertains to both WinX/32 and LightField, curly brackets {
} are
used to denote a LightField term or location.
Refer to
for the conventions utilized throughout this document.
Table 1-1:
Terminology Conventions Used
Topic
Convention Used
WinX/32-Specific Topic
WinX/32 Term/Location
LightField-Specific Topic
LightField Term/Location
WinX/32 and LightField Shared Topic
WinX/32 Term/Location {LightField Term/Location}
Содержание PIXIS-XF
Страница 1: ...www princetoninstruments com PIXIS XF System Manual 4411 0112 Issue 5 January 9 2020...
Страница 8: ...8 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 14: ...14 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 26: ...26 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 36: ...36 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 56: ...56 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 76: ...76 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 88: ...88 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 92: ...92 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 99: ...Appendix B Outline Drawings 99 Figure B 7 Outline Drawing Liquid Cooled PIXIS XF 2048F B 4411 0112_0064...
Страница 102: ...102 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 106: ...106 PIXIS XF System Manual Issue 5 This page is intentionally blank...
Страница 115: ...This page is intentionally blank...