![Teledyne LeCroy T3DSO2000A Series Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/teledyne/lecroy-t3dso2000a-series/lecroy-t3dso2000a-series_user-manual_1080819092.webp)
T3DSO2000A Manual. Page 88
On the bus:
•
ID is displayed in green.
•
LEN (data length) is displayed in light yellow.
•
DATA is displayed in white.
•
CRC is displayed in blue.
•
The red point at the end of a segment indicates there is not enough space on the
display to show the complete content of a frame and some content is hidden.
In the list view:
•
Time — The horizontal offset of the current data frame head relative to the trigger
position.
•
Type — Type of the frame. The data frame is represented by “D” and the remote
frame is represented by “R”.
•
ID — ID of the frame, 11-bits or 29-bits ID are automatically detected.
•
Length — Data length.
•
Data — Data values.
•
CRC — Cycle redundancy check.
•
Ack — Acknowledge bit.
www.
.com
1.800.561.8187