![Teledyne LeCroy T3DSO2000A Series Скачать руководство пользователя страница 135](http://html.mh-extra.com/html/teledyne/lecroy-t3dso2000a-series/lecroy-t3dso2000a-series_user-manual_1080819135.webp)
T3DSO2000A Manual. Page 131
When the FFT tool type is set to markers, the dialog box is as follows:
A. Control markers. Touch to control the display and position
of each marker
B. Marker on peaks. It will automatically mark the peak that
meets the conditions of Search Threshold and Search
Excursion
C. Marker on harmonics. It will automatically mark each
harmonic of FFT waveform
D. Turn on or off the table
E. Turn on or off the frequency display
F. Turn on or off the delta display
G. Set the search threshold. Only peaks larger than the peak
limit can be judged as peaks
H. Set the difference between the peak value and the
minimum amplitude on both sides. The difference should be
greater than the search excursion, which can be determined
as the peak
I. Return to previous menu
Note: The FFT dialog box is longer than the display. Slide the
dialog box area up and down by gestures, or scroll the mouse
wheel to the view non-displayed areas.
The following shows the peak tool enabled for an FFT
waveform:
www.
.com